Evidence map›Paper›PMID 32042773›Full record

ArticleAnnals of translational medicine2019

PEEP guided by electrical impedance tomography during one-lung ventilation in elderly patients undergoing thoracoscopic surgery.

Kun Liu, Chengya Huang, Meiying Xu, Jingxiang Wu, Inez Frerichs, Knut Moeller, Zhanqi Zhao

Registry-linked trialOpen access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05851612 (Comparison of PEEP Titration Guided by Driving Pressure Versus Oxygenation Method Versus Constant PEEP in Patients Undergoing Esophagectomy With One Lung Ventilation in Prone Position), which is not on this map. Cited by 23 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 3 pooled it
2.6field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05851612 nacompletednot on this mapstarted 2023, after this paper: background citation

Comparison of PEEP Titration Guided by Driving Pressure Versus Oxygenation Method Versus Constant PEEP in Patients Undergoing Esophagectomy With One Lung Ventilation in Prone Position

TypeinterventionalSponsorMansoura UniversityRan2023 to 2024Enrolled42ConditionsOne Lung VentilationArmsconstant PEEP, Driving pressure guided PEEP, oxygenation method guided PEEP
3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 3 syntheses or guidelines pooled it, 42 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Trial
  10. Effect of Positive End-Expiratory Pressure (PEEP) Titration in Elderly Patients Undergoing Lobectomy.Medical science monitor : international medical journal of experimental and clinical research · 2022
    Trial
  11. Trial
  12. Trial
  13. Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 2 countries.

Kun LiuDepartment of Anesthesiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China.
Chengya HuangDepartment of Anesthesiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China.
Meiying XuDepartment of Anesthesiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China.
Jingxiang WuDepartment of Anesthesiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China.
Inez FrerichsDepartment of Anesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein, Campus Kiel, Germany.
Knut MoellerInstitute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany.
Zhanqi ZhaoInstitute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany.
Shanghai Chest Hospital · CNShanghai Jiao Tong University · CNAir Force Medical University · CNFurtwangen University · DEUniversity Hospital Schleswig-Holstein · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo examine the influence of positive end-expiratory pressure (PEEP) settings on lung mechanics and oxygenation in elderly patients undergoing thoracoscopic surgery.

methodsOne hundred patients aged >65 years were randomly allocated into either the PEEP

resultsThe optimal PEEP set by EIT was significantly higher (range from 9-13 cmH

conclusionsPEEP values determined with EIT effectively improved oxygenation and lung mechanics during one lung ventilation in elderly patients undergoing thoracoscopic surgery.

Indexed as

Elderly patientselectrical impedance tomography (EIT)lung-protective ventilationone-lung ventilationpositive end-expiratory pressure level

Identifiers

PMID32042773
PMCPMC6989968
OpenAlexW2995533820

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials