ArticleGland surgery2019
Transoral thyroidectomy with a next generation flexible robotic system: A feasibility study in a cadaveric model.
Article in Gland surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Single-port, via a midline approach, Robotic Transaxillary Thyroidectomy (SMART-Thyroidectomy): description of the technique and evaluation of feasibility in the first case series.Journal of robotic surgery · 2026Article
- Institutional evolution of a robotic otolaryngology program across consecutive da Vinci Si, Xi, and SP platform transitions.Journal of robotic surgery · 2026Article
- Robotic thyroidectomy using the da Vinci SP surgical system.Surgical endoscopy · 2026Review
- Single-Port Transoral Robotic Surgery for Head and Neck Lesions and Obstructive Sleep Apnea: A Prospective Real-World Case Series From Taiwan.Laryngoscope investigative otolaryngology · 2026Article
- Robotic Surgery for Head and Neck Tumors: What are the Current Applications?Current oncology reports · 2024Review
- Robotic Slide Tracheoplasty for Pediatric Tracheal Stenosis in Three-Dimensional Printed and Pig Trachea Models.Annals of thoracic surgery short reports · 2024Article
- Single-port robotic transcervical long-segment thoracic tracheal reconstruction: Cadaveric proof-of-concept study.JTCVS techniques · 2022Article
- Transoral robotic thyroidectomy versus transoral endoscopic thyroidectomy: a propensity-score-matched analysis of surgical outcomes.Surgical endoscopy · 2021Article
- Complications of Transoral Thyroidectomy: Overview and Update.Clinical and experimental otorhinolaryngology · 2021Review
- Transoral robotic thyroidectomy using the da Vinci single-port surgical system.Gland surgery · 2020Article
- Single port transoral thyroidectomy.Gland surgery · 2020Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTransoral endoscopic thyroidectomy provides access via the oral vestibule and gas insufflation to provide reliable remote access surgery to perform a total thyroidectomy. The da Vinci SP (Intuitive Surgical Inc., Sunnyvale, CA, USA) is a next generation flexible single port system that offers unique advantages over previous robotic rigid systems. Here we sought to evaluate the feasibility of performing transoral thyroidectomy with this next generation flexible robotic system.
methodsCadaveric dissection with gas insufflation to test the feasibility of performing transoral thyroidectomy with the da Vinci SP.
resultsA 2 cm incision was made in the oral vestibule and the working space created with a 1cm central port and two lateral 5 mm ports. Then an extra small wound protector (Applied Medical, Rancho Santa Margarita, CA) was placed through the central incision after closure of the 5 mm ports. The robotic system was then deployed through the wound protector while insufflation was maintained at ~6 mmHg. Three instrument arms were deployed. A fenestrated bipolar was used to grasp the thyroid gland while Maryland bipolars and monopolar scissors were used to mobilize each hemi lobe of the thyroid. The recurrent laryngeal nerves were seen and preserved bilaterally. After completion of the surgery and removal of the wound protector the vestibular incision was measured to be 3 cm. Further dissection to identify the mental nerves identified each nerve to be >1 cm from the lateral extent of the central incision.
conclusionsIn summary, it is feasible to perform a total thyroidectomy with gas insufflation utilizing this next generation flexible robotic system. Further evaluation will be needed to validate the clinical applicability of this technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.