ArticleInternational journal of molecular sciences2020
Different Frequency of Cyclic Tensile Strain Relates to Anabolic/Catabolic Conditions Consistent with Immunohistochemical Staining Intensity in Tenocytes.
Article in International journal of molecular sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 30 citations in OpenAlex.
- Strontium‑based metal‑organic framework/alendronate‑silk fibroin hydrogels promote tendon‑bone interface healing.Molecular medicine reports · 2026Article
- ROS-responsive hydrogel loaded with capsaicin promotes tenogenic differentiation of tendon stem/progenitor cells and enhances tendon injury repair.Materials today. Bio · 2026Article
- Achilles tendinopathy.Nature reviews. Disease primers · 2025Review
- Fat Expansion Not Fat Infiltration of Muscle Post Rotator Cuff Tendon Tears of the Shoulder: Regenerative Engineering Implications.Regenerative engineering and translational medicine · 2025Article
- Tendon mechanobiology in the context of tendon biofabrication.Frontiers in bioengineering and biotechnology · 2025Review
- Voluntary exercise in mice triggers an anti-osteogenic and pro-tenogenic response in the ankle joint without affecting long bones.Bone reports · 2024Article
- [Study on anti-adhesion effect and mechanism of dynamic and static stress stimulation during early healing process of rat Achilles tendon injury].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024Article
- Tensile Overload Injures Human Alveolar Epithelial Cells through YAP/F-Actin/MAPK Signaling.Biomedicines · 2023Article
- The Contribution of the Nrf2/ARE System to Mechanotransduction in Musculoskeletal and Periodontal Tissues.International journal of molecular sciences · 2023Review
- "Musical dish" efficiently induces osteogenic differentiation of mesenchymal stem cells through music derived microstretch with variable frequency.Bioengineering & translational medicine · 2022Article
- Mechanical overload decreases tenogenic differentiation compared to physiological load in bioartificial tendons.Journal of biological engineering · 2022Article
- Impact of Electrospun Piezoelectric Core-Shell PVDFhfp/PDMS Mesh on Tenogenic and Inflammatory Gene Expression in Human Adipose-Derived Stem Cells: Comparison of Static Cultivation with Uniaxial Cyclic Tensile Stretching.Bioengineering (Basel, Switzerland) · 2022Article
- Dynamic Load Model Systems of Tendon Inflammation and Mechanobiology.Frontiers in bioengineering and biotechnology · 2022Review
- Cyclically stretched ACL fibroblasts emigrating from spheroids adapt their cytoskeleton and ligament-related expression profile.Cell and tissue research · 2021Article
- A low-cost uniaxial cell stretcher for six parallel wells.HardwareX · 2021Article
- The Lack of a Representative Tendinopathy Model Hampers Fundamental Mesenchymal Stem Cell Research.Frontiers in cell and developmental biology · 2021Review
- High stretch cycling inhibits the morphological and biological decidual process in human endometrial stromal cells.Reproductive medicine and biology · 2020Article
- Impact of Uniaxial Stretching on Both Gliding and Traction Areas of Tendon Explants in a Novel Bioreactor.International journal of molecular sciences · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Tenocytes are mechanosensitive cells intimately adapting their expression profile and hence, their phenotype to their respective mechanomilieu. The immunolocalization and expression intensity of tenogenic, anabolic and catabolic markers in tenocytes in response to in vitro mechanical loading have not been monitored by immunohistochemical staining (IHC). Thus, we investigated the association between IHC intensities, different stimulation frequencies, and tenogenic metabolism using a versatile mechanical stretcher. Primary tenocytes obtained from murine Achilles tendons were transferred to poly(dimethylsiloxane) (PDMS) elastomeric chamber. Chambers were cyclically stretched by 5% in uniaxial direction at a variation of tensile frequency (1 or 2 Hz) for 3 h. After stretching, cell physiology, IHC intensities of tendon-related markers, and protein level of the angiogenesis marker vascular endothelial growth factor (VEGF) were evaluated. Cell proliferation in tenocytes stimulated with 1 Hz stretch was significantly higher than with 2 Hz or without stretch, while 2 Hz stretch induced significantly reduced cell viability and proliferation with microscopically detectable apoptotic cell changes. The amount of scleraxis translocated into the nuclei and tenomodulin immunoreactivity of tenocytes treated with stretch were significantly higher than of non-stretched cells. The collagen type-1 expression level in tenocytes stretched at 1 Hz was significantly higher than in those cultivated with 2 Hz or without stretching, whereas the matrix metalloproteinase (MMP)-1 and MMP-13 immunoreactivities of cells stretched at 2 Hz were significantly higher than in those stimulated with 1 Hz or without stretching. The secreted VEGF-protein level of tenocytes stretched at 2 Hz was significantly higher than without stretching. Our IHC findings consistent with cell physiology suggest that appropriate stretching can reproduce in vitro short-term tenogenic anabolic/catabolic conditions and allow us to identify an anabolic stretching profile.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.