Evidence map›Paper›PMID 32040787›Full record

ArticleJournal of experimental orthopaedics2020

Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture.

Michèle N J Keizer, Egbert Otten

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Michèle N J KeizerUniversity of Groningen, University Medical Center Groningen, Center of Human Movement Sciences, Antonius deusinglaan, Groningen, 9713 AV, The Netherlands. m.n.j.keizer@umcg.nl.ORCID http://orcid.org/0000-0001-7623-1612
Egbert OttenUniversity of Groningen, University Medical Center Groningen, Center of Human Movement Sciences, Antonius deusinglaan, Groningen, 9713 AV, The Netherlands.
University Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe first aim was to report the sensitivity of calculated tibiofemoral movements for the choice of placement of the set of femoral markers. The second aim was to report the influence of accuracy of the motion captured positions of the markers on the calculated tibiofemoral movements.

methodsTibiofemoral kinematics during single leg hops for distance were calculated. For the first aim, an experiment was conducted in which four different setups of the femoral markers were used to calculated tibiofemoral movements. For the second aim, an experiment was conducted in which all raw marker positions were mathematically moved independently with the known Vicon position error with a distance and in a random direction in each frame, repeated a hundred times. Each time, the tibiofemoral movements were calculated.

resultsThe first experiment yields that the standard deviation of the calculated anterior tibia translation between marker setups was 0.88 mm and the standard deviation of the external tibia rotation between marker setups was 0.76 degrees. The second experiment yields that the standard deviation was 0.76 mm for anterior tibia translation and 0.38 degrees for external tibia rotation.

conclusionA combined standard deviation of both experiments revealed that transients in anterior tibia translation less than 2.32 mm and external tibia rotations less than 1.70 degrees should be taken with caution. These results are 19.42% of the range of the anterior tibia translation and 13.51% of the rotation range during the jump task. The marker setup should be chosen carefully.

Indexed as

Functional axis of rotationKnee laxityTibia rotationTibia translation

Identifiers

PMID32040787
PMCPMC7010897
OpenAlexW3010051392

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.