ArticleClinical chemistry2020
Development and Clinical Validation of a Sensitive Lateral Flow Assay for Rapid Urine Fentanyl Screening in the Emergency Department.
Article in Clinical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 31 citations in OpenAlex.
- Development of a Quantum Dot-Based Immunochromatographic Assay for Rapid and Sensitive Detection of Non-Medical Etomidate Abuse.Biosensors · 2026Article
- Lateral flow and colorimetric assay for ketamine detection reinforced with deep learning model interfaced with mobile app for smart alert.Mikrochimica acta · 2025Article
- Beyond Fentanyl Test Strips: Investigating Other Urine Drug Test Strips for Drug Checking Applications.Forensic chemistry (Amsterdam, Netherlands) · 2024Article
- Rapid and Sensitive Detection of Fentanyl and Its Analogs by a Novel Chemiluminescence Immunoassay.Clinical chemistry · 2024Article
- Rapid deep learning-assisted predictive diagnostics for point-of-care testing.Nature communications · 2024Article
- A Highly Sensitive and Specific Photonic Crystal-Based Opioid Sensor with Rapid Regeneration.ACS applied materials & interfaces · 2023Article
- Highly Sensitive Fentanyl Detection Based on Nanoporous Electrochemical Immunosensors.IEEE sensors journal · 2022Article
- Article
- Monoclonal Antibodies Application in Lateral Flow Immunochromatographic Assays for Drugs of Abuse Detection.Molecules (Basel, Switzerland) · 2021Review
- Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays.Nature protocols · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
backgroundRapid identification of fentanyl at the point-of-care is critical. Urine fentanyl concentrations in overdose cases start at single-digit nanograms per milliliter. No fentanyl point-of-care assay with a cutoff at single-digit nanograms per milliliter is available.
methodsA competitive lateral flow assay (LFA) was developed using gold nanoparticles and optimized for rapid screening of fentanyl in 5 minutes. Urine samples from 2 cohorts of emergency department (ED) patients were tested using the LFA and LC-MS/MS. The 2 cohorts consisted of 218 consecutive ED patients with urine drug-of-abuse screen orders and 7 ED patients with clinically suspected fentanyl overdose, respectively.
resultsThe LFA detected fentanyl (≥1 ng/mL) and the major metabolite norfentanyl (≥10 ng/mL) with high precision. There was no cross-reactivity with amphetamine, cocaine, morphine, tetrahydrocannabinol, methadone, buprenorphine, naloxone, and acetaminophen at 1000 ng/mL and 0.03%, 0.4%, and 0.05% cross-reactivity with carfentanil, risperidone, and 9-hydroxyrisperidone, respectively. In 218 consecutive ED patients, the prevalence of cases with fentanyl ≥1 ng/mL or norfentanyl ≥10 ng/mL was 5.5%. The clinical sensitivity and specificity of the LFA were 100% (95% CI, 75.8-100%) and 99.5% (95% CI, 97.3-99.9%), respectively. The positive and negative predictive values were 92.3% (95% CI, 66.7-98.6%) and 100% (95% CI, 98.2-100%), respectively. The concordance between the LFA and LC-MS/MS was 100% in the 7 suspected fentanyl overdose cases (5 positive, 2 negative).
conclusionsThe LFA can detect fentanyl and norfentanyl with high clinical sensitivity and specificity in the ED population with rapid fentanyl screening needs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.