Evidence map›Paper›PMID 32040214›Full record

ArticleMedical physics2020

A novel energy layer optimization framework for spot-scanning proton arc therapy.

Wenbo Gu, Dan Ruan, Qihui Lyu, Wei Zou, Lei Dong, Ke Sheng

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
7.0field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 53 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Wenbo GuDepartment of Radiation Oncology, University of California-Los Angeles, Los Angeles, CA, 90095, USA.
Dan RuanDepartment of Radiation Oncology, University of California-Los Angeles, Los Angeles, CA, 90095, USA.
Qihui LyuDepartment of Radiation Oncology, University of California-Los Angeles, Los Angeles, CA, 90095, USA.
Wei ZouDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Lei DongDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Ke ShengDepartment of Radiation Oncology, University of California-Los Angeles, Los Angeles, CA, 90095, USA.
University of California, Los Angeles · USUniversity of Pennsylvania · US

Funding

Development of a versatile robotic radiation therapy systemR44CA183390 · NCI · RADIABEAM TECHNOLOGIES, LLC · PI SHENG, KE, YONEMOTO, JAY · 2017 to 2024
$5.8M
Robust IMPT with automated beam orientation and scanning spot optimizationR01CA230278 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI SHENG, KE · 2019 to 2023
$1.9M
Motion Management of Pancreatic Cancer in MRI-Guided RadiotherapyR01CA188300 · NCI · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI SHENG, KE · 2015 to 2019
$1.7M
(NCI) Developing an Intermediate Energy Linac for Robotic RadiotherapyR43CA183390 · NCI · RADIABEAM TECHNOLOGIES, LLC · PI BOUCHER, SALIME · 2015 to 2016
$265k
NCI NIH HHS R01 CA188300NCI NIH HHS R01 CA230278NCI NIH HHS R43 CA183390NCI NIH HHS R44 CA183390NIH HHS R01CA188300NIH HHS R01CA230278NIH HHS R43CA183390NIH HHS R44CA183390
6 · The paper itself

Abstract

purposeSpot-scanning proton arc therapy (SPAT) is an emerging modality to improve plan conformality and delivery efficiency. A greedy and heuristic method is proposed in the existing SPAT algorithm to select energy layers and sequence energy switching with gantry rotation, which does not promise optimality in either dosimetry or efficiency. We aim to develop a method to solve the energy layer switching and dosimetry optimization problems in an integrated framework for SPAT.

methodsIn an integrated approach, energy layer optimization for spot-scanning proton arc therapy (ELO-SPAT) is formulated with a dose fidelity term, a group sparsity regularization, a log barrier regularization, and an energy sequencing (ES) penalty. The combination of L2,1/2-norm group sparsity regularization and log barrier function allows one energy layer being selected per control point. The ES regularization term sorts the delivery sequence from high energy to low energy to reduce the total energy layer switching time (ELST) and subsequently the total delivery time. Within the ES penalty, the gradient of layer weights between adjacent beams is first calculated along beam direction and then along energy direction. The gradients indicate energy switch patterns between two adjacent beams. The time-wise costly energy switch-up is more heavily penalized in the ES term. This ELO-SPAT method was tested on one frontal base-of-skull (BOS) patient, one chordoma (CHDM) patient with a simultaneous integrated boost, one bilateral head-and-neck (H&N) patient, and one lung (LNG) patient. We compared ELO-SPAT with intensity-modulated proton therapy (IMPT) using discrete beams and SPArc by Ding et al. For the two arc algorithms, both the plans with and without energy sequencing were created and compared.

resultsEnergy layer optimization for spot-scanning proton arc therapy reduced the runtime of optimization by 84% on average compared with the greedy SPArc method. In both the ELO-SPAT plans with and without ES, one energy layer per control point was selected. Without ES regularization, the energy sequence was arbitrary, with around 40-60 switch-up for the tested cases. After adding ES regularization, the number of energy switch-up was reduced to less than 20. Compared with the energy sequenced SPArc plans, the ELO-SPAT plans with ES led to 24% less total ELST for synchrotron plans and 14% less for cyclotron plans. Both the ELO-SPAT and SPArc plans achieved better sparing compared with the IMPT plans for most Organs-at-risks (OARs), with or without ES. Without ES, the ELO-SPAT plans achieved further improvement of the OARs compared with the SPArc plans, with an averaged reduction of OAR [Dmean, Dmax] by [1.57, 3.34] GyRBE. Adding the ES regularization degraded the plan quality, but the ELO-SPAT plans still had comparable or slightly better sparing than the SPArc plans with ES, with an averaged reduction of OAR [Dmean, Dmax] by [1.42, 2.34] GyRBE.

conclusionWe developed a computationally efficient spot-scanning proton arc optimization method, which solved energy layer selection and sequencing in an integrated framework, generating plans with good dosimetry and high delivery efficiency.

Indexed as

Proton TherapyHead and Neck NeoplasmsHumansRadiotherapy Planning, Computer-Assisted

Identifiers

PMID32040214
PMCPMC7234928
OpenAlexW3006403570

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.