Evidence map›Paper›PMID 32039545›Full record

ArticleJournal of applied clinical medical physics2020

Dosimetric evaluation of incorporating the revised V4.0 calibration protocol for breast intraoperative radiotherapy with the INTRABEAM system.

Mubin Y Shaikh, Jay Burmeister, Robin Scott, Lalith K Kumaraswamy, Adrian Nalichowski, Michael C Joiner

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Mubin Y ShaikhDepartment of Radiation Oncology, Rochester Regional, Rochester, NY, USA.
Jay BurmeisterWayne State University School of Medicine, Gershenson Radiation Oncology Center, Barbara Ann Karmanos Cancer Institute, Detroit, MI, USA.
Robin ScottHunstville, AL, USA.
Lalith K KumaraswamyDepartment of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY, USA.
Adrian NalichowskiWayne State University School of Medicine, Gershenson Radiation Oncology Center, Barbara Ann Karmanos Cancer Institute, Detroit, MI, USA.
Michael C JoinerDepartment of Oncology, Gershenson Radiation Oncology Center, Wayne State University, Detroit, USA.
Wayne State University · USRoswell Park Comprehensive Cancer Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In breast-targeted intraoperative radiotherapy (TARGIT) clinical trials (TARGIT-B, TARGIT-E, TARGIT-US), a single fraction of radiation is delivered to the tumor bed during surgery with 1.5- to 5.0-cm diameter spherical applicators and an INTRABEAM x-ray source (XRS). This factory-calibrated XRS is characterized by two depth-dose curves (DDCs) named "TARGIT" and "V4.0." Presently, the TARGIT DDC is used to treat patients enrolled in clinical trials; however, the V4.0 DDC is shown to better represent the delivered dose. Therefore, we reevaluate the delivered prescriptions under the TARGIT protocols using the V4.0 DDC. A 20-Gy dose was prescribed to the surface of the spherical applicator, and the TARGIT DDC was used to calculate the treatment time. For a constant treatment time, the V4.0 DDC was used to recalculate the dosimetry to evaluate differences in dose rate, dose, and equivalent dose in 2-Gy fractions (EQD2) for an α/β = 3.5 Gy (endpoint of locoregional relapse). At the surface of the tumor bed (i.e., spherical applicator surface), the calculations using the V4.0 DDC predicted increased values for dose rate (43-16%), dose (28.6-23.2 Gy), and EQD2 (95-31%) for the 1.5- to 5.0-cm diameter spherical applicator sizes, respectively. In general, dosimetric differences are greatest for the 1.5-cm diameter spherical applicator. The results from this study can be interpreted as a reevaluation of dosimetry or the dangers of underdosage, which can occur if the V4.0 DDC is inadvertently used for TARGIT clinical trial patients. Because the INTRABEAM system is used in TARGIT clinical trials, accurate knowledge about absorbed dose is essential for making meaningful comparisons between radiation treatment modalities, and reproducible treatment delivery is imperative. The results of this study shed light on these concerns.

Indexed as

Intraoperative CarePhantoms, ImagingBreast NeoplasmsCalibrationDose-Response Relationship, RadiationFemaleHumansRadiometryRadiotherapy Planning, Computer-Assistedbreast intraoperative radiotherapyINTRABEAMlinear-quadratic modelspherical applicatorsTARGITV4.0