ArticleIndian heart journal
Intermediate term outcome after electrogram guided segmental ostial pulmonary vein isolation using an 8 mm tip catheter for paroxysmal atrial fibrillation.
Article in Indian heart journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionPulmonary vein isolation (PVI) is the most widely used procedure for ablation in patients with paroxysmal atrial fibrillation (AF). Not withstanding recent advancements in this field, including sophisticated three-dimensional (3D) based imaging and advanced ablation catheters with contact force technology, many patients and healthcare systems in developing countries will not afford such an expensive therapeutic procedure. There are no data from India analyzing the efficacy of PVI for PAF using conventional mapping and ablation. In this article, we have summarized the intermediate term outcome following PVI in patients with PAF using electrogram-based mapping and a 8 mm tip ablation catheter.
methodA total of 42 consecutive patients who underwent PVI for symptomatic PAF not controlled with at least one antiarrhythmic drug were studied in a tertiary care institute from March 2011 to June 2018. Patients with rheumatic AF were excluded. The pulmonary vein (PV) anatomy was assessed by pulmonary angiography during the ablation procedure. Using conventional electrophysiologic mapping, a variable curve Lasso catheter placed in the PVs was used to guide the earliest site of breakthrough. The segmental ostial PVI was performed using a 8 mm tip radiofrequency (RF) ablation catheter. Elimination of all PV ostial potentials and complete entrance block into the PV were considered indicative of complete electrical isolation. Follow-up visits were scheduled at one, three, and six months after the procedure, and every six months thereafter. History, symptom review, clinical examination, and 12-lead ECG were performed at each follow-up.
resultsAt pre-discharge, 34 patients (81%) were in sinus rhythm, while eight patients (19%) continued to have atrial fibrillation. The age of the study population was 51.5 ± 11.7 yrs. The mean follow-up duration was 44 ± 21 months (range 6-84 months). The number of PVs isolated included one (five patients, 11.9%), two (20 patients, 47.6%), three (12 patients, 28.6%), and four (five patients, 11.9%). In 42 patients, a total of 101 PVs were isolated. The right superior PV (RSPV) was isolated in 37 patients, the left superior PV (LSPV) was isolated in 39 patients, the left inferior PV (LIPV) was isolated in 14 patients, and the right inferior PV (RIPV) was isolated in six patients. The procedure duration was 125 ± 29 min and the fluoroscopy time was 47 ± 13 min. The number of patients who remained in sinus rhythm at 1, 6, 12, and 24 months were 34 (81%), 32 (76%), 30 (71%), and 26 (62%), respectively. Two patients of these underwent repeat PVI, which was successful, and they had freedom from AF episodes. Complications were rare. One patient had a minor pericardial effusion, and one patient had transient sinus pauses, which were conservatively managed.
conclusionConventional RF ablation using PV potential-based mapping and ablation with 8 mm tip catheters is safe for patients with PAF. The intermediate term outcome is satisfactory and cost-effective in our setting with limited resources.