Evidence map›Paper›PMID 32030173›Full record

ArticleJournal of environmental health science & engineering2019

Preparation of Carbotrap/silica composite for needle trap field sampling of halogenated volatile organic compounds followed by gas chromatography/mass spectrometry determination.

Ali Poormohammadi, Abdulrahman Bahrami, Alireza Ghiasvand, Farshid Ghorbani Shahna, Maryam Farhadian

Abstract read
In one paragraph

Article in Journal of environmental health science & engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ali Poormohammadi1Center of Excellence for Occupational Health, Research Center for Health Sciences, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran.
Abdulrahman Bahrami1Center of Excellence for Occupational Health, Research Center for Health Sciences, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran.ORCID https://orcid.org/0000-0002-6391-5588
Alireza Ghiasvand2Department of Chemistry, Lorestan University, Khoramabad, Iran.
Farshid Ghorbani Shahna3Centre of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran.
Maryam Farhadian4Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA needle trap device (NTD) was packed with Carbotrap/silica composite sorbent and applied for field sampling of halogenated volatile organic compounds (HVOCs) followed by gas chromatography/mass spectrometry (GC/MS) separation and determination.

methodsCarbotrap B, as a highly pure surface sorbent, was prepared using sol-gel method to improve its surface properties for adsorption/desorption of the target analytes. The effects of important experimental variables on the sampling and determination of trichloroethylene (thrCE) and tetrachloroethylene (tetCE) using the proposed NTD-GC/MS strategy were evaluated and optimized.

resultsThe results showed that sampling temperature and relative humidity interfered with sampling efficiency of the developed method and peak area responses of the analytes decreased with increasing temperature and relative humidity. The peak areas of the analytes increased with raising desorption temperature from 180 to 250 °C, and increasing desorption time from 1 to 3 min. The carryover experiments showed that the carryover effect disappeared after 3 min of desorption time. The Limits of Detection (LODs) and Limits of Quantitation (LOQs) of the analytes were in the range 0.01-0.03 and 0.05-0.09, respectively.

conclusionsThe results indicated that the developed NTD-GC/MS procedure can be used as a technology with high sensitivity for the field sampling and determination of HVOCs.

Indexed as

AirCarbotrap BDry cleaningNeedle trap deviceSilica

Identifiers

PMID32030173
PMCPMC6985406

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.