Evidence map›Paper›PMID 32027468›Full record

ArticleJournal of diabetes investigation2020

Flash glucose monitoring in type 1 diabetes: A comparison with self-monitoring blood glucose.

Naru Babaya, Shinsuke Noso, Yoshihisa Hiromine, Yasunori Taketomo, Fumimaru Niwano, Sawa Yoshida, Sara Yasutake, Yumiko Kawabata, Hiroshi Ikegami

Abstract readComparative Study
In one paragraph

Article in Journal of diabetes investigation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Naru BabayaDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.ORCID https://orcid.org/0000-0003-2466-1228
Shinsuke NosoDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.ORCID https://orcid.org/0000-0002-0943-8450
Yoshihisa HiromineDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.ORCID https://orcid.org/0000-0002-7317-236X
Yasunori TaketomoDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.
Fumimaru NiwanoDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.
Sawa YoshidaDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.
Sara YasutakeDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.
Yumiko KawabataDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.
Hiroshi IkegamiDepartment of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, Osaka-sayama, Osaka, Japan.ORCID https://orcid.org/0000-0001-8808-4605

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

AIMS/

introductionA flash glucose monitoring (FGM) system has become available. To clarify the relationship between FGM and self-monitoring blood glucose (SMBG) values, we compared the two values after simultaneous measurement in Japanese patients with type 1 diabetes, under daily life settings. MATERIALS AND

methodsA total of 20 outpatients with type 1 diabetes were analyzed. When FGM and SMBG were carried out simultaneously (within ±3 min), the values were adopted and each FGM value was matched and compared with the corresponding SMBG value. In addition, we analyzed other cases of simultaneity defined as "within ±2 min," "within ±1 min" and "at the exact same time."

resultsThe percentage of SMBG and FGM values in the clinically acceptable zone A + B in Clarke and consensus error grid analyses were 97.9 and 99.2%, respectively. Deming regression (x-axis: FGM values, y-axis: SMBG values) determined a slope of 0.9128 (95% confidence interval 0.9008-0.9247) and an intercept of +15.94 mg/dL (95% confidence interval 14.05-17.84). FGM values were lower than SMBG values in the lower glucose range, and higher in the higher glucose range. The shorter the time lag between measurements, the higher the rate of concordance between FGM and SMBG values.

conclusionsThe results of this study provided evidence on the reliability of FGM in Japanese patients with type 1 diabetes in home conditions. Based on the results, if an abnormal glucose value is detected by FGM, SBMG should then be used to confirm the result.

Indexed as

AdultAgedBiomarkersBlood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1FemaleFollow-Up StudiesHumansHypoglycemiaHypoglycemic AgentsMaleMiddle AgedMonitoring, AmbulatoryOutpatientsPrognosisBiomarkersBlood GlucoseHypoglycemic AgentsFlash glucose monitoringSelf-monitoring blood glucoseType 1 diabetes

Identifiers

PMID32027468
PMCPMC7477522

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.