Evidence map›Paper›PMID 32025830›Full record

ArticleEuropean radiology2020

Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study.

Waleed Abdellatif, Eric Esslinger, Kevin Kobes, Amanda Wong, Jennifer Powell, Ismail Tawakol Ali, Gordon Andrews, Savvas Nicolaou

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Waleed AbdellatifDepartment of Radiology, University of British Columbia/ Vancouver General Hospital, 899 W 12th Ave, Vancouver, BC, V5Z 1M9, Canada. wtahawy@hotmail.com.ORCID http://orcid.org/0000-0003-2475-7684
Eric EsslingerFaculty of Medicine, University of British Columbia, 317 - 2194 Health Sciences Mall, Vancouver, V6T 1Z3, BC, Canada.
Kevin KobesFaculty of Medicine, University of British Columbia, 317 - 2194 Health Sciences Mall, Vancouver, V6T 1Z3, BC, Canada.
Amanda WongFaculty of Medicine, University of British Columbia, 317 - 2194 Health Sciences Mall, Vancouver, V6T 1Z3, BC, Canada.
Jennifer PowellDepartment of Radiology, University of British Columbia/ Vancouver General Hospital, 899 W 12th Ave, Vancouver, BC, V5Z 1M9, Canada.
Ismail Tawakol AliDepartment of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
Gordon AndrewsDepartment of Radiology, University of British Columbia/ Vancouver General Hospital, 899 W 12th Ave, Vancouver, BC, V5Z 1M9, Canada.
Savvas NicolaouDepartment of Radiology, University of British Columbia/ Vancouver General Hospital, 899 W 12th Ave, Vancouver, BC, V5Z 1M9, Canada.
University of British Columbia · CASunnybrook Health Science Centre · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare the scan acquisition time, radiation dose, subjective and objective image quality of two dual-source CT scanners (DSCT) for detection of acute pulmonary embolism.

methodsTwo hundred twenty-one scans performed on the 2nd-generation DSCT and 354 scans on the 3rd-generation DSCT were included in this large retrospective study. In a randomized blinded design, two radiologists independently reviewed the scans using a 5-point Likert scale. Radiation dose and objective image quality parameters were calculated.

resultsMean acquisition time was significantly lower in the 3rd-generation DSCT (2.81 s ± 0.1 in comparison with 9.7 s ± 0.15 [mean ± SD] respectively; p < 0.0001) with the 3rd generation 3.4 times faster. The mean subjective image quality score was 4.33/5 and 4/5 for the 3rd- and 2nd-generation DSCT respectively (p < 0.0001) with strong interobserver reliability agreement. DLP, CTDI

conclusionObjective and subjective image quality are significantly higher on the 3rd-generation DSCT with significantly lower mean acquisition time and radiation dose. KEY POINTS: • The 3rd-generation DSCT scanner provides an improved image quality, less perceived artifacts, and lower radiation dose in comparison with the 2nd-generation DSCT, when operating in dual-energy (DE) mode. • The 3.4-times-faster 3rd-generation DSCT scanner can be of particular value in patients with chronic lung diseases or breathing difficulties that prevent adequate breathhold.

Indexed as

Radiation DosageTomography Scanners, X-Ray ComputedAdultAgedArtifactsComputed Tomography AngiographyFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedPulmonary EmbolismReproducibility of ResultsRetrospective StudiesSignal-To-Noise RatioTime FactorsDiagnostic imagingDual-energy scanned projectionPulmonary arteryPulmonary embolismRadiography

Identifiers

PMID32025830
OpenAlexW3004920069

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.