Evidence map›Paper›PMID 32024286›Full record

ArticleDentistry journal2020

Virtual Implant Rehabilitation of the Severely Atrophic Maxilla: A Radiographic Study.

Michele Manacorda, Bianca Poletti de Chaurand, Alberto Merlone, Giulia Tetè, Francesca Mottola, Raffaele Vinci

Open access · goldAbstract read
In one paragraph

Article in Dentistry journal, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.4field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Michele ManacordaDepartment of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, via Olgettina n.48, 20123 Milan, Italy.
Bianca Poletti de ChaurandDepartment of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, via Olgettina n.48, 20123 Milan, Italy.ORCID 0000-0001-7320-1709
Alberto MerloneDepartment of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, via Olgettina n.48, 20123 Milan, Italy.
Giulia TetèDepartment of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, via Olgettina n.48, 20123 Milan, Italy.
Francesca MottolaDepartment of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, via Olgettina n.48, 20123 Milan, Italy.
Raffaele VinciDepartment of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, via Olgettina n.48, 20123 Milan, Italy.
Vita-Salute San Raffaele University · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdvanced maxillary atrophy is one of the most common clinical scenarios where implant placement could become difficult. Nevertheless, a volumetric evaluation using a suitable diagnostic software could facilitate the implant planning. The purpose of the present study is to suggest the potential application of the maxillary retro-canine area as the designated location for virtual tilted implants.

methodsA sample of Cone Beam Computed Tomography (CBCT) images from the Department of Dentistry (IRCSS San Raffaele, Milan, Italy) was evaluated. After a 3D anatomical evaluation, tilted implants were virtually positioned in the retro-canine regions. All the implants were inserted using the same procedure at 30° and 45° degrees of tilting. The length, palatal angulation and diameter of the placed implant were identified.

resultsA total of 220 tilted implants were placed. An average implant measurement of 13.51 mm in length and 3.42 mm in diameter were calculated. Additionally, an average buccal-palatal angulation of 6° was identified. Upon statistical analysis, the implant length was found to be significantly higher at 45° degrees of mesio-distal angulation than at 30° degrees (<0.0001).

conclusionsA considerable number of patients show a significant degree of bone atrophy. The implant-supported treatment plan can rely on three-dimensional imaging of the residual bone as a guiding tool to establish the most effective implant position for each specific case. In this study, it was found that an implant could have a greater length if its mesio-distal angulation was more accentuated. In addition, owing to the volumetric evaluation, it was possible to virtually insert tilted implants in almost all of the cases of atrophy. This could lead clinicians to consider the retro-canine area as a viable place to insert a longer tilted implant.

Indexed as

CBCTimplant planningimplant rehabilitationmaxillary atrophyoral surgerytilted implants

Identifiers

PMID32024286
PMCPMC7148484
OpenAlexW3004073181

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.