Evidence map›Paper›PMID 32024158›Full record

ArticleMaterials (Basel, Switzerland)2020

Mechanobiological Approach to Design and Optimize Bone Tissue Scaffolds 3D Printed with Fused Deposition Modeling: A Feasibility Study.

Gianluca Percoco, Antonio Emmanuele Uva, Michele Fiorentino, Michele Gattullo, Vito Modesto Manghisi, Antonio Boccaccio

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Finite element analysis of primary healing implants with different transmucosal designs.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Review
  8. Review
  9. Review
  10. Article
  11. Design of Materials for Bone Tissue Scaffolds.Materials (Basel, Switzerland) · 2021
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Gianluca PercocoDipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Via E. Orabona 4, 70126 Bari, Italy.
Antonio Emmanuele UvaDipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Via E. Orabona 4, 70126 Bari, Italy.
Michele FiorentinoDipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Via E. Orabona 4, 70126 Bari, Italy.
Michele GattulloDipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Via E. Orabona 4, 70126 Bari, Italy.
Vito Modesto ManghisiDipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Via E. Orabona 4, 70126 Bari, Italy.
Antonio BoccaccioDipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Via E. Orabona 4, 70126 Bari, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In spite of the rather large use of the fused deposition modeling (FDM) technique for the fabrication of scaffolds, no studies are reported in the literature that optimize the geometry of such scaffold types based on mechanobiological criteria. We implemented a mechanobiology-based optimization algorithm to determine the optimal distance between the strands in cylindrical scaffolds subjected to compression. The optimized scaffolds were then 3D printed with the FDM technique and successively measured. We found that the difference between the optimized distances and the average measured ones never exceeded 8.27% of the optimized distance. However, we found that large fabrication errors are made on the filament diameter when the filament diameter to be realized differs significantly with respect to the diameter of the nozzle utilized for the extrusion. This feasibility study demonstrated that the FDM technique is suitable to build accurate scaffold samples only in the cases where the strand diameter is close to the nozzle diameter. Conversely, when a large difference exists, large fabrication errors can be committed on the diameter of the filaments. In general, the scaffolds realized with the FDM technique were predicted to stimulate the formation of amounts of bone smaller than those that can be obtained with other regular beam-based scaffolds.

Indexed as

biomaterialsgeometry optimizationmechanobiologyscaffold designtissue engineering

Identifiers

PMID32024158
PMCPMC7041376

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.