Evidence map›Paper›PMID 32023985›Full record

ArticleInternational journal of molecular sciences2020

Therapeutic Efficiency of Multiple Applications of Magnetic Hyperthermia Technique in Glioblastoma Using Aminosilane Coated Iron Oxide Nanoparticles: In Vitro and In Vivo Study.

Gabriel N A Rego, Mariana P Nucci, Javier B Mamani, Fernando A Oliveira, Luciana C Marti, Igor S Filgueiras, João M Ferreira, Caroline C Real, Daniele de Paula Faria, Paloma L Espinha and 5 more

Abstract read
In one paragraph

Article in International journal of molecular sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Magnetic Hyperthermia in Glioblastoma Multiforme Treatment.International journal of molecular sciences · 2024
    Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Neurosurgical Applications of Magnetic Hyperthermia Therapy.Neurosurgery clinics of North America · 2023
    Review
  16. Article
  17. Review
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Gabriel N A RegoHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.ORCID 0000-0003-2011-0373
Mariana P NucciLaboratory of Magnetic resonance (LIM-44), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo 01246-903, SP, Brazil.ORCID 0000-0002-1502-9215
Javier B MamaniHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.
Fernando A OliveiraHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.
Luciana C MartiHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.ORCID 0000-0002-3890-0827
Igor S FilgueirasHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.
João M FerreiraHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.
Caroline C RealLaboratory of Nuclear Medicine (LIM-43), Departamento de Radiologia e Oncologia, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo 01246-903, SP, Brazil.
Daniele de Paula FariaLaboratory of Nuclear Medicine (LIM-43), Departamento de Radiologia e Oncologia, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo 01246-903, SP, Brazil.
Paloma L EspinhaHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.
Daianne M C FantaciniFaculdade de Medicina de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo 4049-900, Brazil.ORCID 0000-0003-2694-0132
Lucas E B SouzaFaculdade de Medicina de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo 4049-900, Brazil.
Dimas T CovasFaculdade de Medicina de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo 4049-900, Brazil.
Carlos A BuchpiguelLaboratory of Nuclear Medicine (LIM-43), Departamento de Radiologia e Oncologia, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo 01246-903, SP, Brazil.
Lionel F GamarraHospital Israelita Albert Einstein, Sao Paulo 05652-900, Brazil.ORCID 0000-0002-3910-0047

Funding

Conselho Nacional de Desenvolvimento Científico e Tecnológico 400856/2016-6Fundação de Amparo à Pesquisa do Estado de São Paulo 2016/21470-3;2014/50983-3
6 · The paper itself

Abstract

Magnetic hyperthermia (MHT) has been shown as a promising alternative therapy for glioblastoma (GBM) treatment. This study consists of three parts: The first part evaluates the heating potential of aminosilane-coated superparamagnetic iron oxide nanoparticles (SPIONa). The second and third parts comprise the evaluation of MHT multiple applications in GBM model, either in vitro or in vivo. The obtained heating curves of SPIONa (100 nm, +20 mV) and their specific absorption rates (SAR) stablished the best therapeutic conditions for frequencies (309 kHz and 557 kHz) and magnetic field (300 Gauss), which were stablished based on three in vitro MHT application in C6 GBM cell line. The bioluminescence (BLI) signal decayed in all applications and parameters tested and 309 kHz with 300 Gauss have shown to provide the best therapeutic effect. These parameters were also established for three MHT applications in vivo, in which the decay of BLI signal correlates with reduced tumor and also with decreased tumor glucose uptake assessed by positron emission tomography (PET) images. The behavior assessment showed a slight improvement after each MHT therapy, but after three applications the motor function displayed a relevant and progressive improvement until the latest evaluation. Thus, MHT multiple applications allowed an almost total regression of the GBM tumor in vivo. However, futher evaluations after the therapy acute phase are necessary to follow the evolution or tumor total regression. BLI, positron emission tomography (PET), and spontaneous locomotion evaluation techniques were effective in longitudinally monitoring the therapeutic effects of the MHT technique.

Indexed as

AnimalsBrain NeoplasmsCell Line, TumorCell ProliferationCell SurvivalGlioblastomaHumansHyperthermia, InducedMagnetite NanoparticlesMaleMiceParticle SizePositron-Emission TomographySilanesTreatment OutcomeXenograft Model Antitumor AssaysMagnetite NanoparticlesSilanesaminosilanebioluminescenceglioblastomamagnetic hyperthermiamotor behaviornanoparticlePET/CTSPION

Identifiers

PMID32023985
PMCPMC7038138

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.