ArticlePhysics in medicine and biology2020
Development of realistic multi-contrast textured XCAT (MT-XCAT) phantoms using a dual-discriminator conditional-generative adversarial network (D-CGAN).
Article in Physics in medicine and biology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Generation of multimodal realistic computational phantoms as a test-bed for validating deep learning-based cross-modality synthesis techniques.Medical & biological engineering & computing · 2026Article
- On-board synthetic 4D MRI generation from 4D CBCT for radiotherapy of abdominal tumors: A feasibility study.Medical physics · 2024Article
- Photon Counting CT and Radiomic Analysis Enables Differentiation of Tumors Based on Lymphocyte Burden.Tomography (Ann Arbor, Mich.) · 2022Article
- Virtual Imaging Trials for Coronavirus Disease (COVID-19).AJR. American journal of roentgenology · 2021Article
- Automatic detection of pulmonary nodules on CT images with YOLOv3: development and evaluation using simulated and patient data.Quantitative imaging in medicine and surgery · 2020Article
- Virtual clinical trials in medical imaging: a review.Journal of medical imaging (Bellingham, Wash.) · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Develop a machine learning-based method to generate multi-contrast anatomical textures in the 4D extended cardiac-torso (XCAT) phantom for more realistic imaging simulations. As a pilot study, we synthesize CT and CBCT textures in the chest region. For training purposes, major organs and gross tumor volumes (GTVs) in chest region were segmented from real patient images and assigned to different HU values to generate organ maps, which resemble the XCAT images. A dual-discriminator conditional-generative adversarial network (D-CGAN) was developed to synthesize anatomical textures in the corresponding organ maps. The D-CGAN was uniquely designed with two discriminators, one trained for the body and the other for the tumor. Various XCAT phantoms were input to the D-CGAN to generate textured XCAT phantoms. The D-CGAN model was trained separately using 62 CT and 63 CBCT images from lung SBRT patients to generate multi-contrast textured XCAT (MT-XCAT). The MT-XCAT phantoms were evaluated by comparing the intensity histograms and radiomic features with those from real patient images using Wilcoxon rank-sum test. The visual examination demonstrated that the MT-XCAT phantoms presented similar general contrast and anatomical textures as CT and CBCT images. The mean HU of the MT-XCAT-CT and MT-XCAT-CBCT were [Formula: see text] and [Formula: see text], compared with that of real CT ([Formula: see text]) and CBCT ([Formula: see text]). The majority of radiomic features from the MT-XCAT phantoms followed the same distribution as the real images according to the Wilcoxon rank-sum test, except for limited second-order features. The study demonstrated the feasibility of generating realistic MT-XCAT phantoms using D-CGAN. The MT-XCAT phantoms can be further expanded to include other modalities (MRI, PET, ultrasound, etc) under the same scheme. This crucial development greatly enhances the value of the phantom for various clinical applications, including testing and optimizing novel imaging techniques, validation of radiomics analysis methods, and virtual clinical trials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.