Evidence map›Paper›PMID 32019608›Full record

ReviewJournal of medical case reports2020

Robotic voluminous paraesophageal hernia repair: a case report and review of the literature.

Nicola Tartaglia, Giovanna Pavone, Alessandra Di Lascia, Fernanda Vovola, Francesca Maddalena, Alberto Fersini, Mario Pacilli, Antonio Ambrosi

Open access · goldAbstract readCase ReportsReview
In one paragraph

Review in Journal of medical case reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Nicola TartagliaDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy. nicola.tartaglia@unifg.it.ORCID http://orcid.org/0000-0001-6845-7080
Giovanna PavoneDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy.
Alessandra Di LasciaDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy.
Fernanda VovolaDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy.
Francesca MaddalenaDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy.
Alberto FersiniDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy.
Mario PacilliDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy.
Antonio AmbrosiDepartment of Medical and Surgical Sciences, University of Foggia, Viale Pinto, 71122, Foggia, Italy.
University of Foggia · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe treatment for sliding esophageal hernia with mild gastroesophageal reflux is usually conservative, but surgical treatment is recommended for refractory sliding esophageal hernia, paraesophageal hernia liable to prolapse, or paraesophageal hernia with ulceration and/or stenosis. Robotic surgery overcomes laparoscopic pitfalls by providing steady-state three-dimensional visualization, augmented dexterity with endo-wrist movements, and superior ergonomics for the surgeon. CASE PRESENTATION: To investigate robotic paraesophageal hernia repair, a literature search was conducted using PubMed with the following key words: mini invasive surgery, robotic surgery, hiatal hernia, and Nissen fundoplication. We present the case of a 44-year-old Italian woman with a 20-year history of gastroesophageal reflux disease refractory to medical treatment, who underwent robotic Nissen fundoplication. In our center, we use the da Vinci® Xi™ Surgical System, which is an advanced tool for minimally invasive surgery.

conclusionsVarious reports published in the literature suggested that the robot-assisted approach was effective and was associated with very low postoperative morbidity and was accompanied by satisfactory symptomatic and anatomical radiological outcomes during a follow-up period. The robotic approach to paraesophageal repair is safe and effective with low complication rates. With increased experience, the operative time, length of stay, and complications decrease without compromising surgical principles.

Indexed as

AdultEsophagogastric JunctionFemaleFundoplicationGastroesophageal RefluxHernia, HiatalHumansRadiographyRobotic Surgical ProceduresGiant or voluminous hiatal herniaHiatal herniaMini invasive surgeryNissen fundoplicationRobotic surgery

Identifiers

PMID32019608
PMCPMC6998085
OpenAlexW3012596791

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.