Evidence map›Paper›PMID 32017130›Full record

ArticleArtificial organs2020

Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

Mehdi Nikfar, Meghdad Razizadeh, Jiafeng Zhang, Ratul Paul, Zhongjun J Wu, Yaling Liu

Open access · greenAbstract read
In one paragraph

Article in Artificial organs, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
2.9field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 45 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. [Progress in the analysis of hemolysis and coagulation models for interventional micro-axial flow blood pumps].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Mehdi NikfarDepartment of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, PA, USA.ORCID https://orcid.org/0000-0003-4575-2727
Meghdad RazizadehDepartment of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, PA, USA.ORCID https://orcid.org/0000-0003-0814-4394
Jiafeng ZhangDepartment of Surgery, University of Maryland, School of Medicine, Baltimore, MD, USA.ORCID https://orcid.org/0000-0001-9544-7785
Ratul PaulDepartment of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, PA, USA.ORCID https://orcid.org/0000-0003-0188-4365
Zhongjun J WuDepartment of Surgery, University of Maryland, School of Medicine, Baltimore, MD, USA.ORCID https://orcid.org/0000-0003-0807-7195
Yaling LiuDepartment of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, PA, USA.ORCID https://orcid.org/0000-0002-4519-3358
Lehigh University · USUniversity of Maryland, Baltimore · US

Funding

Supplement: Hemolysis Prediction Software DevelopmentR01HL131750 · NHLBI · LEHIGH UNIVERSITY · PI LIU, YALING · 2017 to 2021
$2.2M
National Institutes of Health (NIH) R01HL131750NHLBI NIH HHS R01 HL131750NIH HHS R01HL131750
6 · The paper itself

Abstract

This work introduces a new Lagrangian strain-based model to predict the shear-induced hemolysis in biomedical devices. Current computational models for device-induced hemolysis usually utilize empirical fitting of the released free hemoglobin (Hb) in plasma from damaged red blood cells (RBCs). These empirical correlations contain parameters that depend on specific device and operating conditions, thus cannot be used to predict hemolysis in a general device. The proposed algorithm does not have any empirical parameters, thus can presumably be used for hemolysis prediction in various blood-wetting medical devices. In contrast to empirical correlations in which the Hb release is related to the shear stress and exposure time without considering the physical processes, the proposed model links flow-induced deformation of the RBC membrane to membrane permeabilization and Hb release. In this approach, once the steady-state numerical solution of blood flow in the device is obtained under a prescribed operating condition, sample path lines are traced from the inlet of the device to the outlet to calculate the history of the shear stress tensor. In solving the fluid flow, it is assumed that RBCs do not have any influence on the flow pattern. Along each path line, shear stress tensor will be input into a coarse-grained (CG) RBC model to calculate the RBC deformation. Then the correlations obtained from molecular dynamics (MD) simulations are applied to relate the local areal RBC deformation to the perforated area on the RBC membrane. Finally, Hb released out of transient pores is calculated over each path line via a diffusion equation considering the effects of the steric hindrance and increased hydrodynamic drag due to the size of the Hb molecule. The total index of hemolysis (IH) is calculated by integration of released Hb over all the path lines in the computational domain. Hemolysis generated in the Food and Drug Administration (FDA) nozzle and two blood pumps, that is, a CentriMag blood pump (a centrifugal pump) and HeartMate II (an axial pump), for different flow regimes including the laminar and turbulent flows are calculated via the proposed algorithm. In all the simulations, the numerical predicted IH is close to the range of experimental data. The results promisingly indicate that this multiscale approach can be used as a tool for predicting hemolysis and optimizing the hematologic design of other types of blood-wetting devices.

Indexed as

HemolysisAlgorithmsErythrocytesErythrocytes, AbnormalHeart-Assist DevicesHemoglobinsHumansModels, StatisticalShear StrengthStress, MechanicalHemoglobinsaxial pumpcentrifugal pumpFDA nozzleLagrangian strain-based modelmechanical hemolysismultiscale modeling

Identifiers

PMID32017130
PMCPMC7387140
OpenAlexW3004906056

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.