Evidence map›Paper›PMID 32016541›Full record

ArticleWorld journal of surgery2020

Bench Validation of a Handcrafted Prototype Catheter for Intra-gastric Pressure Monitoring.

Alberto Federico García, Julián Chica Yantén, Álvaro Ignacio Sánchez, Jose Luis Aldana, Jorge Humberto Mejía, Daniela Burbano, Camilo Salazar

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Alberto Federico GarcíaCenter for Clinical Research (CIC), Fundación Valle del Lili, Carrera 98 No. 18-49, Torre 7, Piso 3 (CIC), Cali, Colombia. alberto.garcia@fvl.org.co.
Julián Chica YanténCenter for Clinical Research (CIC), Fundación Valle del Lili, Carrera 98 No. 18-49, Torre 7, Piso 3 (CIC), Cali, Colombia.
Álvaro Ignacio SánchezCenter for Clinical Research (CIC), Fundación Valle del Lili, Carrera 98 No. 18-49, Torre 7, Piso 3 (CIC), Cali, Colombia.
Jose Luis AldanaCenter for Clinical Research (CIC), Fundación Valle del Lili, Carrera 98 No. 18-49, Torre 7, Piso 3 (CIC), Cali, Colombia.
Jorge Humberto MejíaCenter for Clinical Research (CIC), Fundación Valle del Lili, Carrera 98 No. 18-49, Torre 7, Piso 3 (CIC), Cali, Colombia.
Daniela BurbanoSchool of Medicine, Universidad ICESI, Calle 18 No. 122-135, Cali, Colombia.ORCID 0000-0002-7025-8790
Camilo SalazarSchool of Medicine, Universidad ICESI, Calle 18 No. 122-135, Cali, Colombia.
Fundación Valle del Lili · COIcesi University · CO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAbdominal compartment syndrome is a sustained intra-abdominal pressure (IAP) >20 mm Hg associated with new organ dysfunction. In order to prevent its development and related complications, IAP monitoring should be performed in patients with risk factors. Although techniques for its monitoring have been developed, they are of high cost and not always available in low- and lower-middle-income countries. Therefore, we aim to develop and validate in a bench model a handcrafted catheter to be used as an alternative method to measure the intra-gastric pressure (IGP) as a surrogate of the IAP.

methodsWe used an acrylic water container as a model of the abdomen and four handcrafted catheters made of a 16 Fr Levin tube with a globe finger tied with silk in the distal end, inflated with 1 cm of air. They were placed on the bottom of the container where the water pressure was directly measured as a gold standard. The agreement between the two measures was assessed with the Bland-Altman method.

resultsWe performed 120 simultaneous measures. The mean pressure difference was 0.218 (95% CI 0.074 to 0.363).

conclusionsThe handcrafted prototype catheter and the direct measure were highly correlated. The new catheter is a reliable and reproducible tool for pressure monitoring. However, before it can be used in the clinical setting for IAP monitoring, validation in human models in a real clinical setting needs to be performed.

Indexed as

CathetersAbdomenHumansIntra-Abdominal HypertensionManometryMonitoring, PhysiologicPressure

Identifiers

PMID32016541
OpenAlexW3004826541

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked