Evidence map›Paper›PMID 32015398›Full record

ArticleScientific reports2020

Resting motor threshold and magnetic field output of the figure-of-8 and the double-cone coil.

Martin Schecklmann, Maximilian Schmaußer, Felix Klinger, Peter M Kreuzer, Lars Krenkel, Berthold Langguth

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Observational
  15. Article
  16. Article
  17. Article
  18. Review
  19. Non-Invasive Neuromodulation for Tinnitus.Journal of audiology & otology · 2020
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Martin SchecklmannDepartment of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany. martin.schecklmann@medbo.de.
Maximilian SchmaußerDepartment of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany.
Felix KlingerFakultät Maschinenbau, Ostbayerische Technische Hochschule, Regensburg, Germany.
Peter M KreuzerDepartment of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany.
Lars KrenkelFakultät Maschinenbau, Ostbayerische Technische Hochschule, Regensburg, Germany.
Berthold LangguthDepartment of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of the double-cone (DC) coil in transcranial magnetic stimulation (TMS) is promoted with the notion that the DC coil enables stimulation of deeper brain areas in contrast to conventional figure-of-8 (Fo8) coils. However, systematic comparisons of these two coil types with respect to the spatial distribution of the magnetic field output and also to the induced activity in superficial and deeper brain areas are limited. Resting motor thresholds of the left and right first dorsal interosseous (FDI) and tibialis anterior (TA) were determined with the DC and the Fo8 coil in 17 healthy subjects. Coils were orientated over the corresponding motor area in an angle of 45 degrees for the hand area with the handle pointing in posterior direction and in medio-lateral direction for the leg area. Physical measurements were done with an automatic gantry table using a Gaussmeter. Resting motor threshold was higher for the leg area in contrast to the hand area and for the Fo8 in contrast to the DC coil. Muscle by coil interaction was also significant providing higher differences between leg and hand area for the Fo8 (about 27%) in contrast to the DC coil (about 15%). Magnetic field strength was higher for the DC coil in contrast to the Fo8 coil. The DC coil produces a higher magnetic field with higher depth of penetration than the figure of eight coil.

Identifiers

PMID32015398
PMCPMC6997368

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.