Evidence map›Paper›PMID 32013154›Full record

ReviewMicromachines2020

Blood and Lymphatic Vasculatures On-Chip Platforms and Their Applications for Organ-Specific In Vitro Modeling.

Aria R Henderson, Hyoann Choi, Esak Lee

Open access · goldAbstract readReview
In one paragraph

Review in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed, 1 pooled it
3.6field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed, 1 synthesis or guideline pooled it, 52 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Materials today. Bio · 2024
    Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Review
  14. Advances in the Model Structure of In Vitro Vascularized Organ-on-a-Chip.Cyborg and bionic systems (Washington, D.C.) · 2024
    Article
  15. Review
  16. Review
  17. Review
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Aria R HendersonNancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, USA.
Hyoann ChoiDepartment of Biological and Environmental Engineering, Cornell University, Ithaca, NY 14853, USA.
Esak LeeNancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, USA.
Cornell University · US

Funding

Cornell University start-up Fund NANancy and Peter Meinig Family Investigator Fund NA
6 · The paper itself

Abstract

The human circulatory system is divided into two complementary and different systems, the cardiovascular and the lymphatic system. The cardiovascular system is mainly concerned with providing nutrients to the body via blood and transporting wastes away from the tissues to be released from the body. The lymphatic system focuses on the transport of fluid, cells, and lipid from interstitial tissue spaces to lymph nodes and, ultimately, to the cardiovascular system, as well as helps coordinate interstitial fluid and lipid homeostasis and immune responses. In addition to having distinct structures from each other, each system also has organ-specific variations throughout the body and both systems play important roles in maintaining homeostasis. Dysfunction of either system leads to devastating and potentially fatal diseases, warranting accurate models of both blood and lymphatic vessels for better studies. As these models also require physiological flow (luminal and interstitial), extracellular matrix conditions, dimensionality, chemotactic biochemical gradient, and stiffness, to better reflect in vivo, three dimensional (3D) microfluidic (on-a-chip) devices are promising platforms to model human physiology and pathology. In this review, we discuss the heterogeneity of both blood and lymphatic vessels, as well as current in vitro models. We, then, explore the organ-specific features of each system with examples in the gut and the brain and the implications of dysfunction of either vasculature in these organs. We close the review with discussions on current in vitro models for specific diseases with an emphasis on on-chip techniques.

Indexed as

blood vesselsbrainsdisease models-on-a-chip platformsintestinesin vitro modelslymphatic vesselsmicro-physiological systemsorgan specificityvasculatures-on-a-chip platforms

Identifiers

PMID32013154
PMCPMC7074693
OpenAlexW3003743290

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.