ArticleIEEE transactions on medical imaging2020
Ultra-Compact Microsystems-Based Confocal Endomicroscope.
Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 28 citations in OpenAlex.
- IL-1α Expands SLC2A1highSPP1highIFNlow Myeloid Cells to Drive Immune Escape and Malignant Transformation of Precancers.Cancer research · 2026Article
- Integrating Optics and Parametrically-Resonant Micro-Scanner Design for Large Working Distance Implantable Microscopy.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2025Article
- Wide-field endoscope accessory for multiplexed fluorescence imaging.Scientific reports · 2023Article
- Miniature side-view dual axes confocal endomicroscope for repetitive in vivo imaging.Biomedical optics express · 2023Article
- Design and test of a rigid endomicroscopic system for multimodal imaging and femtosecond laser ablation.Journal of biomedical optics · 2023Article
- Capacitive Sensing for 2-D Electrostatic MEMS Scanner in a Clinical Endomicroscope.IEEE sensors journal · 2022Article
- Confocal laser endomicroscope with distal MEMS scanner for real-time histopathology.Scientific reports · 2022Article
- Image processing metrics for phase identification of a multiaxis MEMS scanner used in single pixel imaging.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2021Article
- Cell-to-cell variation in gene expression and the aging process.GeroScience · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
Point-of-care medical diagnosis demands immediate feedback on tissue pathology. Confocal endomicroscopy can provide real-time in vivo images with histology-like features. The working channel in medical endoscopes are becoming smaller in dimension. Microsystems methods can produce tiny mechanical scanners. We demonstrate a flexible fiber instrument for in vivo imaging as an endoscope accessory. The optical path is folded on-axis to reduce length while allowing the beam to expand and achieve a numerical aperture of 0.41. A high-speed parametric resonance mirror produces large deflection angles > 13°, and is mounted on a 2 mm diameter chip designed with clamp structures for reduced space. A compact lens assembly provides diffraction-limited lateral and axial resolution of 1.5 and [Formula: see text], respectively. A working distance of [Formula: see text] and field-of-view of [Formula: see text] m are achieved. Miniature apparatus is fabricated to assemble and align the scanhead components. The optics and scanner are packaged in a distal tip with 2.4 mm diameter and 10 mm rigid length. These dimensions allow the endomicroscope to pass forward easily through the 2.8 mm diameter working channel in medical endoscopes commonly used in clinical practice. Fluorescence images are collected in vivo at 10 frames per second in the colon of genetically-engineered mice that spontaneously develop adenomas. A FITC-labeled peptide heterodimer is administered intravenously to provide specific contrast. Sub-cellular structures are visualized to distinguish pre-malignant from normal mucosa. These results demonstrate use of microsystems methods to produce an ultra-compact instrument with sufficiently small dimensions for broad use.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.