Evidence map›Paper›PMID 32010770›Full record

ArticleScience advances2020

Monolithic mtesla-level magnetic induction by self-rolled-up membrane technology.

Wen Huang, Zhendong Yang, Mark D Kraman, Qingyi Wang, Zihao Ou, Miguel Muñoz Rojo, Ananth Saran Yalamarthy, Victoria Chen, Feifei Lian, Jimmy H Ni and 12 more

Abstract read
In one paragraph

Article in Science advances, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. A self-wrapping, bioresorbable neural interface for wireless multimodal therapy of localized peripheral nerve injury.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Microfabrication Technologies for Nanoinvasive and High-Resolution Magnetic Neuromodulation.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
  7. Article
  8. Review
  9. Review
  10. Fast One-Step Fabrication of Highly Regular Microscrolls with Controllable Surface Morphology.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

22 authors.

Wen HuangDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0002-3331-1425
Zhendong YangDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0001-7095-0982
Mark D KramanDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0002-9310-6829
Qingyi WangDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0002-0132-1194
Zihao OuDepartment of Materials Science and Engineering, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0003-2987-7423
Miguel Muñoz RojoDepartment of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.ORCID 0000-0001-9237-4584
Ananth Saran YalamarthyDepartment of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA.
Victoria ChenDepartment of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.
Feifei LianDepartment of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.
Jimmy H NiDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0002-2773-6304
Siyu LiuDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0002-8387-0233
Haotian YuSchool of Microelectronics, Soft Membrane Electronic Technology Laboratory, Hefei University of Technology, Hefei, Anhui 230601, China.
Lei SangSchool of Microelectronics, Soft Membrane Electronic Technology Laboratory, Hefei University of Technology, Hefei, Anhui 230601, China.ORCID 0000-0002-6953-3433
Julian MichaelsDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0002-7631-4036
Dane J SieversDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0003-0996-0238
J Gary EdenDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.
Paul V BraunDepartment of Materials Science and Engineering, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0003-4079-8160
Qian ChenDepartment of Materials Science and Engineering, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0002-1968-441X
Songbin GongDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0001-8147-1282
Debbie G SeneskyDepartment of Aeronautics and Astronautics, Stanford University, Stanford, CA 94305, USA.ORCID 0000-0003-3349-2251
Eric PopDepartment of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.ORCID 0000-0003-0436-8534
Xiuling LiDepartment of Electrical and Computer Engineering and Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL 61801, USA.ORCID 0000-0003-3698-5182

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Monolithic strong magnetic induction at the mtesla to tesla level provides essential functionalities to physical, chemical, and medical systems. Current design options are constrained by existing capabilities in three-dimensional (3D) structure construction, current handling, and magnetic material integration. We report here geometric transformation of large-area and relatively thick (~100 to 250 nm) 2D nanomembranes into multiturn 3D air-core microtubes by a vapor-phase self-rolled-up membrane (S-RuM) nanotechnology, combined with postrolling integration of ferrofluid magnetic materials by capillary force. Hundreds of S-RuM power inductors on sapphire are designed and tested, with maximum operating frequency exceeding 500 MHz. An inductance of 1.24 μH at 10 kHz has been achieved for a single microtube inductor, with corresponding areal and volumetric inductance densities of 3 μH/mm

Identifiers

PMID32010770
PMCPMC6968933

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.