Evidence map›Paper›PMID 32008100›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2020

Comparative effectiveness of PEEK rods versus titanium alloy rods in cervical fusion in a new sheep model.

Jie Wu, Lei Shi, Yanjun Pei, Di Yang, Peng Gao, Xin Xiao, Shuo Guo, Minghui Li, Xiaokang Li, Zheng Guo

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Jie WuDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Lei ShiDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Yanjun PeiDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Di YangDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Peng GaoDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Xin XiaoDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Shuo GuoDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Minghui LiDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China.
Xiaokang LiDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China. lxkfmmu@163.com.
Zheng GuoDepartment of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, Shanxi, China. guozheng@fmmu.edu.cn.
Xijing Hospital · CNAir Force Medical University · CN

Funding

National Key R&D Program of China 2017YFC1104901National Natural Science Foundation of China 51771227National Natural Science Foundation of China 51871239National Natural Science Foundation of China 81772328Natural Science Foundation of Shaanxi Province (CN) 2017JM5137
6 · The paper itself

Abstract

backgroundPedicle screw and rod instrumentation based on titanium can produce satisfying strength and stiffness for spinal fusion. However, excessive stiffness produced by titanium rods may cause stress shielding. Thus, polyetheretherketone (PEEK) rods with a low modulus of elasticity were introduced as substitutes for titanium rods. The purpose of this paper is to compare the effectiveness of PEEK rods versus titanium alloy rods in anterior spinal fusion with a new sheep model.

methodsSheep models of anterior-posterior cervical fusion were innovatively adopted in our study. Twenty-four sheep were randomly divided into a control group and a treatment group that received anterior-posterior cervical fixation with titanium rods or PEEK rods, respectively. Then, surgical segments were harvested and assessed by X-ray, micro-CT and histological examination to evaluate the efficiency of bone fusion.

resultsNo complications related to fixation were found during the research process. The results of the X-ray showed a stronger spinal fusion in the PEEK rod groups than in the titanium rod group at 12 weeks postoperatively, and both groups underwent bone fusion at 24 weeks postoperatively. The results of micro-CT showed that fixation with PEEK rods achieved better bone ingrowth at an early postoperative stage (12 weeks) compared to fixation with titanium rods (bone volume fraction (BVF): 20.26 ± 4.36% vs 14.48 ± 3.49%, p < 0.05). The same trend was detected in the histological analysis, where the mineralized bone fraction in the experiment group (21.01 ± 3.48%) was significantly higher than that in the control group (16.73 ± 2.95%). In addition, better osseointegration was found in the experiment group at the early postoperative stage at 12 weeks (bone apposition (BA): 16.22 ± 3.24% vs 11.67 ± 3.63%, p < 0.05). However, there were no significant differences at 24 weeks postoperatively.

conclusionPEEK rods can be used safely in a sheep model of anterior-posterior cervical fixation. Compared to traditional titanium rods, earlier and more evident bone fusion was found in the PEEK rods group. These slides can be retrieved under Electronic Supplementary Material.

Indexed as

Spinal FusionAlloysAnimalsBenzophenonesKetonesLumbar VertebraeModels, AnimalPolyethylene GlycolsPolymersSheepTitaniumAlloysBenzophenonesKetonespolyetheretherketonePolyethylene GlycolsPolymersTitaniumCervical vertebraIntersomatic cagePolyetheretherketone rodsSheep modelTitanium alloy rods

Identifiers

PMID32008100
OpenAlexW3003559816

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked