ReviewBiosensors & bioelectronics2020
Recent advances in lab-on-a-chip technologies for viral diagnosis.
Review in Biosensors & bioelectronics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 94 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
94 citing papers in PubMed, 248 citations in OpenAlex.
- Bio-Based Microfluidics With Snail Slime: A By-Product of Agriculture Plays an Exciting Role in the Chemistry of Microfluidic Reaction Chambers.Macromolecular rapid communications · 2026Article
- A knowledge-guided deep learning framework for quantitative nucleic acid testing.Briefings in bioinformatics · 2026Article
- Proteomic identification and histopathological validation of candidate biomarkers CA1, HBB, Torsin A, andFrontiers in medicine · 2026Article
- Next-generation viral detection through AI-enhanced nanotechnology: advances, challenges, and future directions.Frontiers in molecular biosciences · 2026Article
- Low-power microfluidic RT-LAMP system with real-time fluorescence detection for portable nucleic acid testing.Mikrochimica acta · 2025Article
- Lab-on-PCB with integrated DNA amplification and electroanalytical detection for point-of-care diagnostics.Scientific reports · 2025Article
- Recent advances in bio-microsystem integration and Lab-on-PCB technology.Microsystems & nanoengineering · 2025Review
- Canine papillomavirus: status of diagnostic methods and vaccine innovations.Virology journal · 2025Review
- Polymerase Chain Reaction Chips for Biomarker Discovery and Validation in Drug Development.Micromachines · 2025Review
- Review
- Innovative Diagnostic Approaches and Challenges in the Management of HIV: Bridging Basic Science and Clinical Practice.Life (Basel, Switzerland) · 2025Review
- Portable solutions for plant pathogen diagnostics: development, usage, and future potential.Frontiers in microbiology · 2025Review
- Hybrid paper/PDMS microfluidic device integrated with RNA extraction and recombinase polymerase amplification for detection of norovirus in foods.Applied and environmental microbiology · 2024Article
- Capillary-assisted flat-field formation: a platform for advancing nanoparticle tracking analysis in an integrated on-chip optofluidic environment.Nanophotonics (Berlin, Germany) · 2024Article
- Development of a label-free photoelectrochemical immunosensor for novel astrovirus detection.Mikrochimica acta · 2024Article
- Increasing Optical Path Lengths in Micro-Fluidic Devices Using a Multi-Pass Cell.Micromachines · 2024Article
- Self-Assembled Block Copolymers as a Facile Pathway to Create Functional Nanobiosensor and Nanobiomaterial Surfaces.Polymers · 2024Review
- An integrated microfluidic platform for nucleic acid testing.Microsystems & nanoengineering · 2024Article
- Different Roles of Surface Chemistry and Roughness of Laser-Induced Graphene: Implications for Tunable Wettability.ACS applied nano materials · 2023Article
- Bio-inspired microfluidics: A review.Biomicrofluidics · 2023Review
34 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The global risk of viral disease outbreaks emphasizes the need for rapid, accurate, and sensitive detection techniques to speed up diagnostics allowing early intervention. An emerging field of microfluidics also known as the lab-on-a-chip (LOC) or micro total analysis system includes a wide range of diagnostic devices. This review briefly covers both conventional and microfluidics-based techniques for rapid viral detection. We first describe conventional detection methods such as cell culturing, immunofluorescence or enzyme-linked immunosorbent assay (ELISA), or reverse transcription polymerase chain reaction (RT-PCR). These methods often have limited speed, sensitivity, or specificity and are performed with typically bulky equipment. Here, we discuss some of the LOC technologies that can overcome these demerits, highlighting the latest advances in LOC devices for viral disease diagnosis. We also discuss the fabrication of LOC systems to produce devices for performing either individual steps or virus detection in samples with the sample to answer method. The complete system consists of sample preparation, and ELISA and RT-PCR for viral-antibody and nucleic acid detection, respectively. Finally, we formulate our opinions on these areas for the future development of LOC systems for viral diagnostics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials