Evidence map›Paper›PMID 31999560›Full record

ReviewBiosensors & bioelectronics2020

Recent advances in lab-on-a-chip technologies for viral diagnosis.

Hanliang Zhu, Zdenka Fohlerová, Jan Pekárek, Evgenia Basova, Pavel Neužil

Open access · greenAbstract readReview
In one paragraph

Review in Biosensors & bioelectronics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 94 papers.

0numbers the graph read from it
0cells of the map it votes in
94citing papers in PubMed
15.7field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

94 citing papers in PubMed, 248 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Review

34 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Hanliang ZhuMinistry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China.
Zdenka FohlerováCentral European Institute of Technology, Brno University of Technology, 612 00, Brno, Czech Republic; Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, 616 00, Brno, Czech Republic.
Jan PekárekCentral European Institute of Technology, Brno University of Technology, 612 00, Brno, Czech Republic; Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, 616 00, Brno, Czech Republic.
Evgenia BasovaCentral European Institute of Technology, Brno University of Technology, 612 00, Brno, Czech Republic.
Pavel NeužilMinistry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China; Central European Institute of Technology, Brno University of Technology, 612 00, Brno, Czech Republic; Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, 616 00, Brno, Czech Republic. Electronic address: pavel.neuzil@npwu.edu.cn.
Brno University of Technology · CZNorthwestern Polytechnical University · CNCentral European Institute of Technology · CZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The global risk of viral disease outbreaks emphasizes the need for rapid, accurate, and sensitive detection techniques to speed up diagnostics allowing early intervention. An emerging field of microfluidics also known as the lab-on-a-chip (LOC) or micro total analysis system includes a wide range of diagnostic devices. This review briefly covers both conventional and microfluidics-based techniques for rapid viral detection. We first describe conventional detection methods such as cell culturing, immunofluorescence or enzyme-linked immunosorbent assay (ELISA), or reverse transcription polymerase chain reaction (RT-PCR). These methods often have limited speed, sensitivity, or specificity and are performed with typically bulky equipment. Here, we discuss some of the LOC technologies that can overcome these demerits, highlighting the latest advances in LOC devices for viral disease diagnosis. We also discuss the fabrication of LOC systems to produce devices for performing either individual steps or virus detection in samples with the sample to answer method. The complete system consists of sample preparation, and ELISA and RT-PCR for viral-antibody and nucleic acid detection, respectively. Finally, we formulate our opinions on these areas for the future development of LOC systems for viral diagnostics.

Indexed as

Lab-On-A-Chip DevicesBiosensing TechniquesDNA, ViralEnzyme-Linked Immunosorbent AssayEquipment DesignHumansMicrofluidic Analytical TechniquesNucleic AcidsPoint-of-Care SystemsReal-Time Polymerase Chain ReactionVirus DiseasesDNA, ViralNucleic AcidsCommercializationImmunoassaysLOCMicrofluidicNucleic acid amplificationViral detection

Identifiers

PMID31999560
PMCPMC7126858
OpenAlexW3002683399

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked