Evidence map›Paper›PMID 31996842›Full record

ArticleNature protocols2020

Facilitating chemical and biochemical experiments with electronic microcontrollers and single-board computers.

Gurpur Rakesh D Prabhu, Tzu-Hsien Yang, Chun-Yao Hsu, Chun-Pei Shih, Chun-Ming Chang, Pei-Han Liao, Hsiang-Ting Ni, Pawel L Urban

Abstract read
PubMed Publisher
In one paragraph

Article in Nature protocols, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 43 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Prototyping an ionization source for non-engineers.Journal of mass spectrometry : JMS · 2024
    Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Gurpur Rakesh D Prabhu *Department of Chemistry, National Tsing Hua University, Hsinchu, Taiwan.ORCID http://orcid.org/0000-0002-3237-212X
Tzu-Hsien Yang *Department of Chemistry, National Tsing Hua University, Hsinchu, Taiwan.
Chun-Yao HsuDepartment of Chemistry, National Tsing Hua University, Hsinchu, Taiwan.
Chun-Pei ShihDepartment of Chemistry, National Tsing Hua University, Hsinchu, Taiwan.
Chun-Ming ChangDepartment of Chemistry, National Tsing Hua University, Hsinchu, Taiwan.
Pei-Han LiaoDepartment of Chemistry, National Tsing Hua University, Hsinchu, Taiwan.
Hsiang-Ting NiDepartment of Chemistry, National Tsing Hua University, Hsinchu, Taiwan.
Pawel L UrbanDepartment of Chemistry, National Tsing Hua University, Hsinchu, Taiwan. urban@mx.nthu.edu.tw.ORCID http://orcid.org/0000-0003-3471-045X
National Tsing Hua University · TWNational Yang Ming Chiao Tung University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Since the advent of modern science, researchers have had to rely on their technical skills or the support of specialized workshops to construct analytical instruments. The notion of the 'fourth industrial revolution' promotes construction of customized systems by individuals using widely available, inexpensive electronic modules. This protocol shows how chemists and biochemists can utilize a broad range of microcontroller boards (MCBs) and single-board computers (SBCs) to improve experimental designs and address scientific questions. We provide seven example procedures for laboratory routines that can be expedited by implementing this technology: (i) injection of microliter-volume liquid plugs into microscale capillaries for low-volume assays; (ii) transfer of liquid extract to a mass spectrometer; (iii) liquid-gas extraction of volatile organic compounds (called 'fizzy extraction'), followed by mass spectrometric detection; (iv) monitoring of experimental conditions over the Internet cloud in real time; (v) transfer of analytes to a mass spectrometer via a liquid microjunction interface, data acquisition, and data deposition into the Internet cloud; (vi) feedback control of a biochemical reaction; and (vii) optimization of sample flow rate in direct-infusion mass spectrometry. The protocol constitutes a primer for chemists and biochemists who would like to take advantage of MCBs and SBCs in daily experimentation. It is assumed that the readers have not attended any courses related to electronics or programming. Using the instructions provided in this protocol and the cited material, readers should be able to assemble simple systems to facilitate various procedures performed in chemical and biochemical laboratories in 1-2 d.

Indexed as

ComputersBiochemistryElectrochemical TechniquesSoftware

Identifiers

PMID31996842
OpenAlexW3003323045

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.