Evidence map›Paper›PMID 31996149›Full record

ArticleBMC medical imaging2020

Patient-adapted organ absorbed dose and effective dose estimates in pediatric 18F-FDG positron emission tomography/computed tomography studies.

Brian M Quinn, Yiming Gao, Usman Mahmood, Neeta Pandit-Taskar, Gerald Behr, Pat Zanzonico, Lawrence T Dauer

Registry-linked trialAbstract readComparative Study
In one paragraph

Article in BMC medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05555550 (Evaluation of 18F-Fluciclovine PET-MRI as a Biomarker of Response in Pediatric and Young Adult Patients With Low Grade Gliomas), which is not on this map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05555550 early_phase1recruitingnot on this mapstarted 2026, after this paper: background citation

Evaluation of 18F-Fluciclovine PET-MRI as a Biomarker of Response in Pediatric and Young Adult Patients With Low Grade Gliomas (LGG)

TypeinterventionalSponsorChildren's Hospital of PhiladelphiaRan2026 to 2027Enrolled30ConditionsGlioma, Low-grade Glioma, Low Grade Glioma of Brain, Glioma, MalignantArms18F-Fluciclovine
3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. MIRD Pamphlet No. 34, Part 2: Benchmarking of MIRDct Software for CT Organ Dose Estimation.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
    Article
  2. Article
  3. Article
  4. Automated Measurement of Effective Radiation Dose byTomography (Ann Arbor, Mich.) · 2024
    Article
  5. EANM procedural recommendations for managing the paediatric patient in diagnostic nuclear medicine.European journal of nuclear medicine and molecular imaging · 2023
    Review
  6. Review
  7. Article
  8. Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Brian M QuinnDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA. quinnb@mskcc.org.ORCID 0000-0002-1664-7437
Yiming GaoDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
Usman MahmoodDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
Neeta Pandit-TaskarDepartment of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
Gerald BehrDepartment of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
Pat ZanzonicoDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
Lawrence T DauerDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

backgroundOrgan absorbed doses and effective doses can be used to compare radiation exposure among medical imaging procedures, compare alternative imaging options, and guide dose optimization efforts. Individual dose estimates are important for relatively radiosensitive patient populations such as children and for radiosensitive organs such as the eye lens. Software-based dose calculation methods conveniently calculate organ dose using patient-adjusted and examination-specific inputs.

methodsOrgan absorbed doses and effective doses were calculated for 429 pediatric 18F-FDG PET-CT patients. Patient-adjusted and scan-specific information was extracted from the electronic medical record and scanner dose-monitoring software. The VirtualDose and OLINDA/EXM (version 2.0) programs, respectively, were used to calculate the CT and the radiopharmaceutical organ absorbed doses and effective doses. Patients were grouped according to age at the time of the scan as follows: less than 1 year old, 1 to 5 years old, 6 to 10 years old, 11 to 15 years old, and 16 to 17 years old.

resultsThe mean (+/- standard deviation, range) total PET plus CT effective dose was 14.5 (1.9, 11.2-22.3) mSv. The mean (+/- standard deviation, range) PET effective dose was 8.1 (1.2, 5.7-16.5) mSv. The mean (+/- standard deviation, range) CT effective dose was 6.4 (1.8, 2.9-14.7) mSv. The five organs with highest PET dose were: Urinary bladder, heart, liver, lungs, and brain. The five organs with highest CT dose were: Thymus, thyroid, kidneys, eye lens, and gonads.

conclusionsOrgan and effective dose for both the CT and PET components can be estimated with actual patient and scan data using commercial software. Doses calculated using software generally agree with those calculated using dose conversion factors, although some organ doses were found to be appreciably different. Software-based dose calculation methods allow patient-adjusted dose factors. The effort to gather the needed patient data is justified by the resulting value of the characterization of patient-adjusted dosimetry.

Indexed as

AdolescentAge DistributionChildChild, PreschoolFemaleFluorodeoxyglucose F18HumansInfantMalePositron Emission Tomography Computed TomographyRadiation DosageRadiopharmaceuticalsSoftwareFluorodeoxyglucose F18RadiopharmaceuticalsCT dosimetryEffective dosePediatricPET/CT dosimetryPET dosimetry

Identifiers

PMID31996149
PMCPMC6988339

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.