Evidence map›Paper›PMID 31996129›Full record

ArticleBMC bioinformatics2020

pSpatiocyte: a high-performance simulator for intracellular reaction-diffusion systems.

Satya N V Arjunan, Atsushi Miyauchi, Kazunari Iwamoto, Koichi Takahashi

Abstract readEvaluation Study
In one paragraph

Article in BMC bioinformatics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Tools for computational analysis of moving boundary problems in cellular mechanobiology.Wiley interdisciplinary reviews. Systems biology and medicine · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Satya N V ArjunanRIKEN Center for Biosystems Dynamics Research, Suita, Osaka, Japan. satya@riken.jp.ORCID http://orcid.org/0000-0002-2913-3347
Atsushi MiyauchiResearch Organization for Information Science and Technology, Chuo, Kobe, Japan.
Kazunari IwamotoRIKEN Center for Biosystems Dynamics Research, Suita, Osaka, Japan.
Koichi TakahashiRIKEN Center for Biosystems Dynamics Research, Suita, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStudies using quantitative experimental methods have shown that intracellular spatial distribution of molecules plays a central role in many cellular systems. Spatially resolved computer simulations can integrate quantitative data from these experiments to construct physically accurate models of the systems. Although computationally expensive, microscopic resolution reaction-diffusion simulators, such as Spatiocyte can directly capture intracellular effects comprising diffusion-limited reactions and volume exclusion from crowded molecules by explicitly representing individual diffusing molecules in space. To alleviate the steep computational cost typically associated with the simulation of large or crowded intracellular compartments, we present a parallelized Spatiocyte method called pSpatiocyte.

resultsThe new high-performance method employs unique parallelization schemes on hexagonal close-packed (HCP) lattice to efficiently exploit the resources of common workstations and large distributed memory parallel computers. We introduce a coordinate system for fast accesses to HCP lattice voxels, a parallelized event scheduler, a parallelized Gillespie's direct-method for unimolecular reactions, and a parallelized event for diffusion and bimolecular reaction processes. We verified the correctness of pSpatiocyte reaction and diffusion processes by comparison to theory. To evaluate the performance of pSpatiocyte, we performed a series of parallelized diffusion runs on the RIKEN K computer. In the case of fine lattice discretization with low voxel occupancy, pSpatiocyte exhibited 74% parallel efficiency and achieved a speedup of 7686 times with 663552 cores compared to the runtime with 64 cores. In the weak scaling performance, pSpatiocyte obtained efficiencies of at least 60% with up to 663552 cores. When executing the Michaelis-Menten benchmark model on an eight-core workstation, pSpatiocyte required 45- and 55-fold shorter runtimes than Smoldyn and the parallel version of ReaDDy, respectively. As a high-performance application example, we study the dual phosphorylation-dephosphorylation cycle of the MAPK system, a typical reaction network motif in cell signaling pathways.

conclusionspSpatiocyte demonstrates good accuracies, fast runtimes and a significant performance advantage over well-known microscopic particle methods in large-scale simulations of intracellular reaction-diffusion systems. The source code of pSpatiocyte is available at https://spatiocyte.org.

Indexed as

Models, BiologicalSoftwareAlgorithmsComputer SimulationDiffusionMAP Kinase Signaling SystemPhosphorylationCell simulationHexagonal close-packed latticeMessage passing interfaceMitogen-activated protein kinaseMonte Carlo methodparallelized Gillespie’s direct-methodParticle reaction-diffusion

Identifiers

PMID31996129
PMCPMC6990473

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.