Evidence map›Paper›PMID 31995836›Full record

ArticleApplied clinical informatics2020

Evaluating Usability of a Touchless Image Viewer in the Operating Room.

Markus Bockhacker, Hannah Syrek, Max Elstermann von Elster, Sebastian Schmitt, Henning Roehl

Open access · bronzeAbstract readEvaluation Study
In one paragraph

Article in Applied clinical informatics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 2 pooled it
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 2 syntheses or guidelines pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Human-Device Interaction in the Life Science Laboratory.Advances in biochemical engineering/biotechnology · 2022
    Article
  5. Review
  6. [Digital OR].Der Unfallchirurg · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Markus BockhackerDepartment of Orthopedic Surgery, Diakonissen Hospital, Mannheim, Germany.ORCID 0000-0002-8395-0305
Hannah Syrekmbits imaging GmbH, Heidelberg, Germany.ORCID 0000-0003-2161-4987
Max Elstermann von ElsterDepartment of Sports Surgery, ATOS Clinic, Heidelberg, Germany.ORCID 0000-0002-2084-6420
Sebastian SchmittDepartment of Orthopedic Surgery, Diakonissen Hospital, Mannheim, Germany.
Henning RoehlDepartment of Orthopedic Surgery, Diakonissen Hospital, Mannheim, Germany.
Diakonissenkrankenhaus · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAvailability of patient-specific image data, gathered from preoperatively conducted studies, like computed tomography scans and magnetic resonance imaging studies, during a surgical procedure is a key factor for surgical success and patient safety. Several alternative input methods, including recognition of hand gestures, have been proposed for surgeons to interact with medical image viewers during an operation. Previous studies pointed out the need for usability evaluation of these systems.

objectivesWe describe the accuracy and usability of a novel software system, which integrates gesture recognition via machine learning into an established image viewer.

methodsThis pilot study is a prospective, observational trial, which asked surgeons to interact with software to perform two standardized tasks in a sterile environment, modeled closely to a real-life situation in an operating room. To assess usability, the validated "System Usability Scale" (SUS) was used. On a technical level, we also evaluated the accuracy of the underlying neural network.

resultsThe neural network reached 98.94% accuracy while predicting the gestures during validation. Eight surgeons with an average of 6.5 years of experience participated in the usability study. The system was rated on average with 80.25 points on the SUS.

conclusionThe system showed good overall usability; however, additional areas of potential improvement were identified and further usability studies are needed. Because the system uses standard PC hardware, it made for easy integration into the operating room.

Indexed as

Operating RoomsHumansImaging, Three-DimensionalNeural Networks, ComputerReproducibility of ResultsSoftwareSurgeonsTask Performance and AnalysisUser-Computer Interface

Identifiers

PMID31995836
PMCPMC6989265
OpenAlexW3003824302

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked