Evidence map›Paper›PMID 31995610›Full record

ArticlePloS one2020

Can the fusion of motion capture and 3D medical imaging reduce the extrinsic variability due to marker misplacements?

Xavier Gasparutto, Jennifer Wegrzyk, Kevin Rose-Dulcina, Didier Hannouche, Stéphane Armand

Abstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xavier GasparuttoLaboratory of Kinesiology Willy Taillard, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.ORCID 0000-0001-8617-6522
Jennifer WegrzykLaboratory of Kinesiology Willy Taillard, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.
Kevin Rose-DulcinaLaboratory of Kinesiology Willy Taillard, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.
Didier HannoucheDivision of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland.
Stéphane ArmandLaboratory of Kinesiology Willy Taillard, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.ORCID 0000-0001-9144-4982

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In clinical gait analysis, measurement errors impede the reliability and repeatability of the measurements. This extrinsic variability can potentially mislead the clinical interpretation of the analysis and should thus be minimised. Skin marker misplacement has been identified as the largest source of extrinsic variability between measurements. The goal of this study was to test whether the fusion of motion capture and 3D medical imaging could reduce extrinsic variability due to skin marker misplacement. The fusion method consists in using anatomical landmarks identified with 3D medical imaging to correct marker misplacements. To assess the reduction of variability accountable to the fusion method, skin marker misplacements were voluntarily introduced in the measurement of the pelvis and hip kinematics during gait for two patients scheduled for unilateral hip arthroplasty and two patients that underwent unilateral hip arthroplasty. The root mean square deviation was reduced by -78 ± 15% and the range of variability by -80 ± 16% for the pelvis and hip kinematics in average. These results showed that the fusion method could significantly reduce the extrinsic variability due to skin marker misplacement and thus increase the reliability and repeatability of motion capture measurements. However, the identification of anatomical landmarks via medical imaging is a new source of extrinsic variability that should be assessed before considering the fusion method for clinical applications.

Indexed as

Fiducial MarkersMovementAgedArthroplasty, Replacement, HipBiomechanical PhenomenaFemaleGaitHip JointHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMaleModels, BiologicalPelvisRange of Motion, ArticularSkin

Identifiers

PMID31995610
PMCPMC6988975

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.