Can the fusion of motion capture and 3D medical imaging reduce the extrinsic variability due to marker misplacements?
Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Sensor-to-Bone Calibration with the Fusion of IMU and Bi-Plane X-rays.Sensors (Basel, Switzerland) · 2024Article
- Reliability, accuracy, and minimal detectable difference of a mixed concept marker set for finger kinematic evaluation.Heliyon · 2023Article
- 3D free-hand ultrasound to register anatomical landmarks at the pelvis and localize the hip joint center in lean and obese individuals.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In clinical gait analysis, measurement errors impede the reliability and repeatability of the measurements. This extrinsic variability can potentially mislead the clinical interpretation of the analysis and should thus be minimised. Skin marker misplacement has been identified as the largest source of extrinsic variability between measurements. The goal of this study was to test whether the fusion of motion capture and 3D medical imaging could reduce extrinsic variability due to skin marker misplacement. The fusion method consists in using anatomical landmarks identified with 3D medical imaging to correct marker misplacements. To assess the reduction of variability accountable to the fusion method, skin marker misplacements were voluntarily introduced in the measurement of the pelvis and hip kinematics during gait for two patients scheduled for unilateral hip arthroplasty and two patients that underwent unilateral hip arthroplasty. The root mean square deviation was reduced by -78 ± 15% and the range of variability by -80 ± 16% for the pelvis and hip kinematics in average. These results showed that the fusion method could significantly reduce the extrinsic variability due to skin marker misplacement and thus increase the reliability and repeatability of motion capture measurements. However, the identification of anatomical landmarks via medical imaging is a new source of extrinsic variability that should be assessed before considering the fusion method for clinical applications.