Evidence map›Paper›PMID 31989100›Full record

ArticleBMC rheumatology2020

Dual energy CT findings in gout with rapid kilovoltage-switching source with gemstone scintillator detector.

Elin Svensson, Ylva Aurell, Lennart T H Jacobsson, Anton Landgren, Valgerdur Sigurdardottir, Mats Dehlin

Open access · goldAbstract read
In one paragraph

Article in BMC rheumatology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. What Has Dual Energy CT Taught Us About Gout?Current rheumatology reports · 2021
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Elin Svensson1Department of Radiology at Institute of Clinical Sciences, Sahlgrenska Academy, Gothenburg, Sweden.
Ylva Aurell1Department of Radiology at Institute of Clinical Sciences, Sahlgrenska Academy, Gothenburg, Sweden.
Lennart T H Jacobsson2Department of Rheumatology and Inflammation Research, Sahlgrenska Academy, Gothenburg, Sweden.
Anton Landgren2Department of Rheumatology and Inflammation Research, Sahlgrenska Academy, Gothenburg, Sweden.
Valgerdur Sigurdardottir2Department of Rheumatology and Inflammation Research, Sahlgrenska Academy, Gothenburg, Sweden.
Mats Dehlin2Department of Rheumatology and Inflammation Research, Sahlgrenska Academy, Gothenburg, Sweden.
University of Gothenburg · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA definite diagnosis of gout requires demonstration of monosodium urate crystals in synovial fluid or in tophi, which in clinical practice today seldom is done. Dual energy CT (DECT) has repeatedly been shown to be able to detect monosodium urate crystals in tissues, hence being an alternative method to synovial fluid microscopy. The vast majority of these studies were performed with CT scanners with two X-ray tubes. In the present study we aim to investigate if and at what locations DECT with rapid kilovoltage-switching source with gemstone scintillator detector (GSI) can identify MSU crystals in patients with clinically diagnosed gout. We also performed a reliability study between two independent readings.

methodsPatients with new or established gout who had been examined with DECT GSI scanning of the feet at Sahlgrenska University Hospital, Mölndal between 2015 and 2018 were identified. Their medical records were sought for gout disease characteristics using a structured protocol. Urate deposits in MTP1, MTP 2-5, ankle/midfoot joints and tendons were scored semiquantatively in both feet and presence of artifacts in nail and skin as well as beam hardening and noise were recorded. Two radiologists performed two combined readings and scoring of the images, thus consensus was reached over the scoring at each occasion (Espeland et al., BMC Med Imaging. 2013;13:4). The two readings were compared with kappa statistics.

resultsDECT GSI could identify urate deposits in the feet of all 55 participants with gout. Deposits were identified in the MTP-joints of all subjects but were also present in ankle/midfoot joints and tendons in 96 and 75% respectively. Deposition of urate was predicted by longer disease duration (Spearman's Rho 0.64,

conclusionThe validity of DECT GSI in gout is supported by the identification of urate in all patients with clinical gout and the good correlations with clinical characteristics. The occurrence of artifacts was relatively low with expected locations.

Indexed as

Diagnostic imagingDual energy CTFootGoutMonosodium urate crystals

Identifiers

PMID31989100
PMCPMC6966802
OpenAlexW3008520428

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.