ArticleScientific reports2020
Secondary cancer risk after radiation therapy for breast cancer with different radiotherapy techniques.
Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
41 citing papers in PubMed, 1 synthesis or guideline pooled it, 88 citations in OpenAlex.
- The use of Hybrid Techniques in Whole-Breast Radiotherapy: A Systematic Review.Technology in cancer research & treatmentPooled it
- The impact of orthogonal image-guided frequency on positioning error correction and dose in postoperative radiotherapy for breast cancer.BMC cancer · 2026Article
- Objective-function-guided automated VMAT planning reduces OAR dose, low-dose exposure, and inter-planner variability in breast radiotherapy.Scientific reports · 2026Article
- The impact of positioning errors on the dose distribution of hypofractionated radiotherapy for left-sided radical breast cancer.Frontiers in oncology · 2026Article
- Dosimetric and Secondary Cancer Risk Comparison after Radiation Therapy for Breast Cancer with Three-Dimensional Conformal Radiotherapy, and Helical Tomotherapy.Asian Pacific journal of cancer prevention : APJCP · 2025Article
- Performance evaluation of a new automated skin flash method for radiotherapy of breast cancer.Physics and imaging in radiation oncology · 2025Article
- Application of a simple skin flap to repair large defects in a patient with radiotherapy‑induced skin squamous cell carcinoma after breast cancer surgery: A case report.Oncology letters · 2025Article
- Occurrence of Malignancies Other than Breast and Ovarian Cancer in Female Carriers of aCancers · 2025Article
- Impact of immobilization system angle, body mass index and breast size on breast radiotherapy accuracy using EPID-only setup.Heliyon · 2025Article
- Nanotechnology in brain cancer treatment: The role of gold nanoparticles as therapeutic enhancers.Ibrain · 2025Review
- Current trends in breast cancer genetics, risk factors, and screening strategies.Journal of biological methods · 2025Review
- Evaluation of helical tomotherapy as an alternative for left-sided breast cancer patients not compliant with deep inspiration breath hold.Technical innovations & patient support in radiation oncology · 2024Article
- Dosimetric analysis of six whole-breast irradiation techniques in supine and prone positions.Scientific reports · 2024Article
- Deep inspiratory breath-hold radiotherapy on a Helical Tomotherapy unit: Workflow and early outcomes in patients with left-sided breast cancer.Technical innovations & patient support in radiation oncology · 2024Article
- Incidence of Nonkeratinocyte Skin Cancer After Breast Cancer Radiation Therapy.JAMA network open · 2024Article
- Second Malignancy Probabilities in Patients With Breast Cancer Treated With Conventional Versus Hypofractionated External Beam Radiation Therapy in the Adjuvant Setting.Clinical oncology (Royal College of Radiologists (Great Britain)) · 2024Article
- Article
- A novel x-Ray and γ-Ray combination strategy for radiotherapy after breast-conserving surgery in patients with right breast cancer.Frontiers in oncology · 2024Article
- Radiation-associated secondary malignancies: a novel opportunity for applying immunotherapies.Cancer immunology, immunotherapy : CII · 2023Review
- Novel Insights into Circular RNAs in Metastasis in Breast Cancer: An Update.Non-coding RNA · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of this study was to estimate the radiation-related secondary cancer risks in organs during the treatment of breast cancer with different radiotherapy techniques, such as three-dimensional conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). The treatment plans for 26 patients with breast cancer who received whole-breast irradiation at a dose of 50 Gy included tangential field 3D-CRT with hard-wedges (W-TF), tangential field IMRT (2F-IMRT), multiple field IMRT (6F-IMRT), and double partial arcs (VMAT). Patients were divided into three groups according to the distance between the contralateral breast (CB) and the body of the sternum. Setup error was simulated by moving the isocenter, and the dose distribution was then recalculated without changing the field fluency distribution. Based on the linear-exponential, the plateau, and the full mechanistic dose-response models, the organ equivalent dose and excess absolute risk were calculated from dose-volume histograms to estimate the secondary cancer risks in organs. Compared with 3D-CRT, IMRT and VMAT showed excellent results regarding tumor conformity and homogeneity; however, the low dose volume to organs was considerably higher in 6F-IMRT and VMAT. Secondary cancer risks for 2F-IMRT were comparable or slightly lower than for W-TF, but considerably lower than for 6F-IMRT or VMAT. After setup error simulation, there was a small increase in secondary cancer risk for 2F-IMRT and an increase of 159% and 318% for 6F-IMRT and VMAT, respectively, compared with W-TF. Although these results were obtained in most patients, they did not necessarily apply to every individual. The secondary cancer risks in the CB decreased significantly in correlation with increased distance for all alternative techniques, although they were higher in VMAT and lower in 2F-IMRT regardless of the distance. After setup error simulation, the increased changes in secondary cancer risks in the CB were comparable between 2F-IMRT, 6F-IMRT, and VMAT, suggesting that the secondary cancer risks in the CB mainly depend on radiotherapy techniques and distance, although the effect of setup error cannot be ignored. In the contralateral lung (CL), the secondary cancer risks were almost independent from distance and depended mainly on radiotherapy techniques; they were rarely affected by setup error. VMAT was associated with a higher secondary cancer risk in the CL. For the ipsilateral lung (IL), the secondary cancer risks were higher than those in other organs because the IL receives high doses to achieve tumor control, and they were relatively lower in VMAT. This warrants special consideration when estimating the secondary cancer risk to the IL. The study results suggested that the optimal radiotherapy method for breast cancer should be determined on an individual basis and according to the balance between secondary cancer risks related to anatomic diversity and setup error, which can prevent blind selection of techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.