Evidence map›Paper›PMID 31986231›Full record

SynthesisThe Cochrane database of systematic reviews2020

Sound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants.

Abdulraoof Almadhoob, Arne Ohlsson

Abstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed, 5 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 5 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Trial
  7. Trial
  8. Article
  9. Article
  10. Review
  11. Review
  12. Observational
  13. Article
  14. Article
  15. Article
  16. Article
  17. Observational
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors.

Abdulraoof AlmadhoobSalmaniya Medical Complex, Manama, Bahrain.
Arne OhlssonUniversity of Toronto, Departments of Paediatrics, Obstetrics and Gynaecology and Institute of Health Policy, Management and Evaluation, Toronto, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInfants in the neonatal intensive care unit (NICU) are subjected to stress, including sound of high intensity. The sound environment in the NICU is louder than most home or office environments and contains disturbing noises of short duration and at irregular intervals. There are competing auditory signals that frequently challenge preterm infants, staff and parents. The sound levels in NICUs often exceed the maximum acceptable level of 45 decibels (dB), recommended by the American Academy of Pediatrics. Hearing impairment is diagnosed in 2% to 10% of preterm infants versus 0.1% of the general paediatric population. Noise may cause apnoea, hypoxaemia, alternation in oxygen saturation, and increased oxygen consumption secondary to elevated heart and respiratory rates and may, therefore, decrease the amount of calories available for growth. Elevated levels of speech are needed to overcome the noisy environment in the NICU, thereby increasing the negative impacts on staff, newborns, and their families. High noise levels are associated with an increased rate of errors and accidents, leading to decreased performance among staff. The aim of interventions included in this review is to reduce sound levels to 45 dB or less. This can be achieved by lowering the sound levels in an entire unit, treating the infant in a section of a NICU, in a 'private' room, or in incubators in which the sound levels are controlled, or reducing the sound levels that reaches the individual infant by using earmuffs or earplugs. By lowering the sound levels that reach the neonate, the resulting stress on the cardiovascular, respiratory, neurological, and endocrine systems can be diminished, thereby promoting growth and reducing adverse neonatal outcomes.

objectivesPrimary objective To determine the effects of sound reduction on growth and long-term neurodevelopmental outcomes of neonates. Secondary objectives 1. To evaluate the effects of sound reduction on short-term medical outcomes (bronchopulmonary dysplasia, intraventricular haemorrhage, periventricular leukomalacia, retinopathy of prematurity). 2. To evaluate the effects of sound reduction on sleep patterns at three months of age. 3. To evaluate the effects of sound reduction on staff performance. 4. To evaluate the effects of sound reduction in the neonatal intensive care unit (NICU) on parents' satisfaction with the care. SEARCH

methodsWe searched the Cochrane Central Register of Controlled Trials (The Cochrane Library), MEDLINE, EMBASE, CINAHL, abstracts from scientific meetings, clinical trials registries (clinicaltrials.gov; controlled-trials.com; and who.int/ictrp), Pediatric Academic Societies Annual meetings 2000 to 2014 (Abstracts2View SELECTION CRITERIA: Preterm infants (< 32 weeks' postmenstrual age (PMA) or < 1500 g birth weight) cared for in the resuscitation area, during transport, or once admitted to a NICU or a stepdown unit. DATA COLLECTION AND ANALYSIS: We performed data collection and analyses according to the Cochrane Neonatal Review Group. MAIN

resultsOne small, high quality study assessing the effects of silicone earplugs versus no earplugs qualified for inclusion. The original inclusion criteria in our protocol stipulated an age of < 48 hours at the time of initiating sound reduction. We made a deviation from our protocol and included this study in which some infants would have been > 48 hours old. There was no significant difference in weight at 34 weeks postmenstrual age (PMA): mean difference (MD) 111 g (95% confidence interval (CI) -151 to 374 g) (n = 23). There was no significant difference in weight at 18 to 22 months corrected age between the groups: MD 0.31 kg, 95% CI -1.53 to 2.16 kg (n = 14). There was a significant difference in Mental Developmental Index (Bayley II) favouring the silicone earplugs group at 18 to 22 months corrected age: MD 14.00, 95% CI 3.13 to 24.87 (n = 12), but not for Psychomotor Development Index (Bayley II) at 18 to 22 months corrected age: MD -2.16, 95% CI -18.44 to 14.12 (n =12). AUTHORS'

conclusionsTo date, only 34 infants have been enrolled in a randomised controlled trial (RCT) testing the effectiveness of reducing sound levels that reach the infants' ears in the NICU. Based on the small sample size of this single trial, we cannot make any recommendations for clinical practice. Larger, well designed, conducted and reported trials are needed.

Indexed as

Stress, PhysiologicalEar Protective DevicesEmployee Performance AppraisalHealth PersonnelHumansInfant, NewbornInfant, PrematureInfant, Very Low Birth WeightIntensive Care Units, NeonatalNoiseRandomized Controlled Trials as TopicSound

Identifiers

PMID31986231
PMCPMC6989790

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.