ArticleInvestigative radiology2020
Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT.
Article in Investigative radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 32 citations in OpenAlex.
- High performance of low-dose ultrahigh-resolution photon-counting detector CT for sacroiliac joint assessment in axial spondyloarthritis.European journal of radiology open · 2026Article
- K-Edge imaging using a clinical dual-source photon-counting CT system.Journal of applied clinical medical physics · 2026Article
- Pushing the limits of spatial resolution in clinical PCD-CT using a dedicated high-resolution convolutional neural network (HR-CNN).Medical physics · 2026Article
- Photon-counting CT versus energy-integrating detector and flat-panel CT for cadaveric wrist arthrography with additional tin filter dose reduction.European radiology experimental · 2025Article
- Mechanistic insights into non-coding RNAs regulate autophagy in chondrocytes and their contribution to osteoarthritis.Frontiers in medicine · 2025Review
- Photon-counting in dual-contrast-enhanced computed tomography: a proof-of-concept quantitative biomechanical assessment of articular cartilage.Scientific reports · 2024Article
- A missed opportunity: A scoping review of the effect of sex and age on osteoarthritis using large animal models.Osteoarthritis and cartilage · 2024Article
- Computed tomography-current status and future directions for arthritis imaging.Therapeutic advances in musculoskeletal disease · 2024Review
- Photon-Counting Detector Computed Tomography: A Promising New Technique for Multiple Myeloma Evaluation That Warrants Further Investigation.Korean journal of radiology · 2023Article
- Quantification of cartilage and subchondral bone cysts on knee specimens based on a spectral photon-counting computed tomography.Scientific reports · 2023Article
- Ultra-High-Resolution Photon-Counting Detector CT Arthrography of the Ankle: A Feasibility Study.Diagnostics (Basel, Switzerland) · 2023Article
- Early knee OA definition-what do we know at this stage? An imaging perspective.Therapeutic advances in musculoskeletal disease · 2023Review
- Deep Learning-Based CT Imaging to Evaluate the Therapeutic Effects of Acupuncture and Moxibustion Therapy on Knee Osteoarthritis.Computational and mathematical methods in medicine · 2022Article
- Ultra-high resolution computed tomography of joints: practical recommendations for acquisition protocol optimization.Quantitative imaging in medicine and surgery · 2021Article
- Photon Counting CT: Clinical Applications and Future Developments.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Spectral CT imaging of human osteoarthritic cartilage via quantitative assessment of glycosaminoglycan content using multiple contrast agents.APL bioengineering · 2021Article
- High Resolution, Full Field-of-View, Whole Body Photon-Counting Detector CT: System Assessment and Initial Experience.Proceedings of SPIE--the International Society for Optical Engineering · 2021Article
- Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography: A Feasibility Animal Study.Investigative radiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
Abstract
objectiveThe aim of this study was to grade cartilage damage in a swine model of osteoarthritis using a whole-body photon-counting detector (PCD) CT. MATERIALS AND
methodsA multienergy phantom containing gadolinium (Gd) (2, 4, 8, and 16 mg/mL) and hydroxyapatite (200 and 400 mg/cc) was scanned using a PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs, D50 reconstruction kernel) to serve as calibration for material decomposition and to assess quantification accuracy. Osteoarthritis was induced in Yucatan miniswine (n = 8) using 1.2 mg monoiodoacetate (MIA) injected into a randomized knee, whereas the contralateral control knee received saline. Twenty-one days later, a contrast bolus (gadoterate meglumine, 4 mL/knee) was intra-articularly administered into both knees. The knees were simultaneously scanned on the PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs). Multienergy images were reconstructed with a sharp "V71" kernel and a quantitative "D50" kernel. Image denoising was applied to the V71 images before grading cartilage damage, and an iterative material decomposition technique was applied to D50 images to generate the Gd maps. Two radiologists blinded to the knee injection status graded the cartilage integrity based on a modified International Cartilage Repair Society scoring system. Histology was performed on excised cartilage using methylene blue/basic fuchsin. Statistical analysis of grade distribution was performed using an exact test of omnibus symmetry with P < 0.05 considered significant.
resultsMaterial decomposed images from the multienergy phantom scan showed delineation and quantification of Gd and hydroxyapatite with a root-mean-squared error of 0.3 mg/mL and 18.4 mg/cc, respectively. In the animal cohort, the radiologists reported chondromalacia in the MIA knees with International Cartilage Repair Society scores ranging from grade 1 (cartilage heterogeneity, n = 4 knees) to grade 3 (up to 100% cartilage loss, n = 4 knees). Grade 1 was characterized by cartilage heterogeneity and increased joint space in the patellofemoral compartment, whereas grade 3 was characterized by cartilage erosion and bone-on-bone articulation in the patellofemoral compartment. All control knees were scored as grade 0 (normal cartilage). Significant difference (P = 0.004) was observed in the grade distribution between the MIA and control knees. Gross examination of the excised knees showed cartilage lesions in the grade 3 MIA knees. The Gd maps from material decomposition showed lower contrast levels in the joint space of the MIA knee compared with the contralateral control knee due to joint effusion. Histology revealed chondrocyte loss in the MIA knee cartilage confirming the chondrotoxic effects of MIA on cartilage matrix.
conclusionsWe demonstrated a high-resolution and quantitative PCD-CT arthrography technique for grading cartilage damage in a large animal model of osteoarthritis. Photon-counting detector CT offers simultaneous high-resolution and multienergy imaging capabilities that allowed morphological assessment of cartilage loss and quantification of contrast levels in the joint as a marker of joint disease. Cartilage damage in the MIA knees was graded using PCD-CT images, and the image-based findings were further confirmed using histology and gross examination of the excised knees.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.