ArticleMedical physics2020
Multi-energy inter-pixel coincidence counters for charge sharing correction and compensation in photon counting detectors.
Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 29 citations in OpenAlex.
- From Materials to Medical Images: Translating Perovskite-Based X-Ray Detectors Toward Clinical Imaging.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- A coincidence-based response matrix for correction of charge sharing spectral distortions in photon counting detectors.Medical physics · 2026Article
- Clinical benefits and current challenges of photon-counting detector CT in vascular imaging.Radiology advances · 2026Review
- Ring Artifact Reduction in Photon Counting CT Using Redundant Sampling and Autocalibration.IEEE transactions on medical imaging · 2026Article
- Spatial resolution improvements for photon counting detectors using coincidence counting and frequency weighted reconstruction.Medical physics · 2025Article
- Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Number of energy windows for photon counting detectors: is more actually more?Journal of medical imaging (Bellingham, Wash.) · 2024Article
- Direct energy binning for photon counting detectors: Simulation study.Medical physics · 2024Article
- [A comprehensive review on photon-counting computed tomography: Principles, technical hurdles and analysis of clinical applications].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023Review
- Theoretical comparison and optimization of cadmium telluride and gallium arsenide photon-counting detectors for contrast-enhanced spectral mammography.Journal of medical imaging (Bellingham, Wash.) · 2023Article
- Energy-integrating-detector multi-energy CT: Implementation and a phantom study.Medical physics · 2021Article
- Assessment of multi-energy inter-pixel coincidence counters for photon-counting detectors at the presence of charge sharing and pulse pileup: A simulation study.Medical physics · 2021Article
- Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Assessment of Multienergy Interpixel Coincidence Counters (MEICC) for Charge Sharing Correction or Compensation for Photon Counting Detectors With Boxcar Signals.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.Physics in medicine and biology · 2021Article
- CdTe Based Energy Resolving, X-ray Photon Counting Detector Performance Assessment: The Effects of Charge Sharing Correction Algorithm Choice.Sensors (Basel, Switzerland) · 2020Article
- Comparison of quantitative imaging characteristics between a new, larger-FOV 1000 fps high-speed angiographic (HSA) photon-counting detector (Aries) with a smaller HSA detector (Actaeon).Proceedings of SPIE--the International Society for Optical EngineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
Abstract
purposeSmaller pixel sizes of x-ray photon counting detectors (PCDs) are advantageous for count rate capabilities but disadvantageous for charge sharing. With charge sharing, the energy of an x-ray photon may be split and one photon may produce two or more counts at adjacent pixels, both at lower energies than the incident energy. This "double-counting" increases noise variance and degrades the spectral response. Overall, it has a significantly negative impact on the performance of PCD-based computed tomography (CT). Charge sharing is induced by the detection physics and occurs regardless of count rates; thus, it is impossible to avoid. We propose in this paper a method that has a potential to address both noise and bias added by charge sharing.
methodsWe propose applying a multi-energy inter-pixel coincidence counter (MEICC) technique, which uses energy-dependent coincidence counters, keeps the book of charge sharing events during data acquisition, and provides the exact number of charge sharing occurrences, which can be used to either correct or compensate for them after the acquisition is completed. MEICC does not interfere with the primary counting process; therefore, PCDs with MEICC will remain as fast as those without MEICC. MEICC can be implemented using current electronics technology because its inter-pixel coincidence counters used to handle digital data are rather simple. We evaluated Cramér-Rao lower bound (CRLB) of PCDs with and without MEICC using a Monte Carlo simulation.
resultsWhen the number of energy windows was four or larger and eight neighboring pixels were used, the CRLBs of 225-µm PCD with MEICC normalized by those of the current PCD with the same number of windows were 0.361-0.383 for water density images of two basis functions, which was only 5.7-16.4% worse than those of a PCD without charge sharing (which were at 0.329-0.358). In contrast, the normalized CRLBs of the PCD with one coincidence counter were 0.466-0.499, which were 37.3-45.6% worse than the PCD without charge sharing. The use of eight neighboring pixels provided ~10% better CRLB values than four neighboring pixels for MEICC. With four energy windows, decreasing the number of coincidence counters from 16 to 9 only slightly increased the CRLB from 0.255 to 0.269 (which corresponded to as little as a 5.5% change). The normalized CRLBs of MEICC for K-edge imaging (gold) were 0.295-0.426, while those of the one coincidence counter were 0.926-0.959 and the ideal PCDs were 0.126-0.146.
conclusionsThe proposed MEICC provides spectral information that can be used to address charge sharing problems in PCDs and is expected to satisfy the requirements for clinical x-ray CT. MEICC is very effective, especially for K-edge imaging, which requires accurate spectral information.