Evidence map›Paper›PMID 31981696›Full record

ArticleJournal of cardiac failure2020

HVAD Flow Waveform Estimates Left Ventricular Filling Pressure.

Teruhiko Imamura, Nikhil Narang, Daniel Rodgers, Daisuke Nitta, Jonathan Grinstein, Takeo Fujino, Gene Kim, Ann Nguyen, Valluvan Jeevanandam, Gabriel Sayer and 1 more

Abstract read
In one paragraph

Article in Journal of cardiac failure, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Teruhiko ImamuraDepartment of Medicine, University of Chicago Medical Center, Chicago, Illinois; Second Department of Medicine, University of Toyama, Toyama, Japan.
Nikhil NarangAdvocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois.
Daniel RodgersDepartment of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Daisuke NittaDepartment of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Jonathan GrinsteinDivision of Cardiology, MedStar Heart and Vascular Institute Advanced Heart Failure and Cardiac Transplantation, NW, Washington, DC.
Takeo FujinoDepartment of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Gene KimDepartment of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Ann NguyenDepartment of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Valluvan JeevanandamDepartment of Surgery, University of Chicago Medical Center, Chicago, Illinois.
Gabriel SayerDivision of Cardiology, Columbia University Irving Medical Center, New York, New York.
Nir UrielDivision of Cardiology, Columbia University Irving Medical Center, New York, New York. Electronic address: nu2126@cumc.columbia.edu.

Funding

MULTIDISCIPLINARY CARDIAC SCIENCEST32HL007381 · NHLBI · UNIVERSITY OF CHICAGO · PI JEANNE M DECARA, Yoav Gilad · 1985 to 2026
$12.5M
NHLBI NIH HHS T32 HL007381
6 · The paper itself

Abstract

backgroundHVAD left ventricular assist device flow waveforms provides graphical real-time information linking device performance with invasive hemodynamics. Previous studies have demonstrated a good correlation between the slopes of the ventricular filling phase slope (VFPS) and directly measured pulmonary capillary wedge pressure (PCWP). We aimed to validate the utility of VFPS to estimate PCWP and predict clinical outcomes.

methodsIn this prospective blinded study, screenshots from the HVAD monitor and simultaneous invasive hemodynamic measurements were obtained. Each screenshot was digitized and the VFPS was calculated by 2 independent reviewers who were blinded to the hemodynamic results. The equation PCWP = 7.053 +1.365 × (VFPS) was derived from a previously published dataset and the estimated PCWP was correlated to the actually measured PCWP.

resultsOne hundred thirty-one sets of simultaneous measurements (VFPS and PCWP) were obtained from 27 HVAD patients (mean age 55 years, 47% male). A previously proposed cutoff of VFPS ≥5.8 L/min/s predicted PCWP ≥ 18 mmHg with 91.5% sensitivity and 95.2% specificity with the area under curve of 0.987. The estimated PCWP significantly correlated with measured PCWP (R

conclusionsVFPS of the HVAD flow waveform is a novel noninvasive parameter that can estimate PCWP.

Indexed as

Heart-Assist DevicesHeart FailureFemaleHeart VentriclesHumansMaleMiddle AgedProspective StudiesPulmonary Wedge PressureHeart failureheartwareventricular assist device

Identifiers

PMID31981696
PMCPMC7347084

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.