ArticleMagma (New York, N.Y.)2020
Sensitivity and uniformity improvement of phased array MR images using inductive coupling and RF detuning circuits.
Article in Magma (New York, N.Y.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging.Sensors (Basel, Switzerland) · 2022Article
- A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo improve sensitivity and uniformity of MR images obtained using a phased array RF coil, an inductively coupled secondary resonator with RF detuning circuits at 300 MHz was designed. MATERIALS AND
methodsA secondary resonator having detuning circuits to turn off the resonator during the transmit mode was constructed. The secondary resonator was located at the opposite side of the four-channel phased array to improve sensitivity and uniformity of the acquired MR images. Numerical simulations along with phantom and in vivo experiments were conducted to evaluate the designed secondary resonator.
resultsThe numerical simulation results of |B
conclusionThe designed secondary resonator having detuning circuits improved sensitivity and uniformity of mouse MR images acquired using the four-channel phased array.
Indexed as
Identifiers
31980963What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.