Evidence map›Paper›PMID 31980876›Full record

ArticleArchives of orthopaedic and trauma surgery2020

The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model.

Jan Theopold, Stefan Schleifenbaum, Alexander Georgi, Michael Schmidt, Ralf Henkelmann, Georg Osterhoff, Pierre Hepp

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jan TheopoldDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany. jan.theopold@medizin.uni-leipzig.de.ORCID http://orcid.org/0000-0003-2884-8030
Stefan SchleifenbaumZESBO, Zentrum Zur Erforschung Der Stütz- Und Bewegungsorgane, Semmelweisstrasse 14, 04103, Leipzig, Germany.
Alexander GeorgiDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
Michael SchmidtZESBO, Zentrum Zur Erforschung Der Stütz- Und Bewegungsorgane, Semmelweisstrasse 14, 04103, Leipzig, Germany.
Ralf HenkelmannDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
Georg OsterhoffDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
Pierre HeppDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeNumerous techniques have been described for the tibial-sided graft preparation in anterior cruciate ligament (ACL) reconstruction. The use of less suture material for graft preparation is thought to improve ingrowth and to reduce the risk for infection. At the same time, the suture construct should be strong enough to resist the surgeon's pull during tensioning of the transplant.

methodsIn total, 39 fresh-frozen procine deep flexor tendons were used and prepared as four-strand grafts. In the three-suture group (n = 19), graft preparation was performed using three tibial-sided sutures, with each tendon end sutured separately. In the one-suture group (n = 20), a modified graft preparation using only one tibial-sided suture was applied. Each sample underwent load-to-failure testing (N

resultsThe biomechanical testing of the two different suture constructs showed a significantly higher load-to-failure for the three-suture group (711 N ± 91 N) compared to the one-suture group (347 N ± 24 N) (p = 0.0001). In both groups, the mode of failure was a tear of the suture in all samples. A failure of the suture-tendon interface was not observed in any case. The median maximal tension force on the construct applied by the 26 volunteers was 134 N (range 73-182 N).

conclusionThe presented single-suture tendon graft preparation resisted to smaller failure loads than the conventional three-suture technique. However, no failures in the suture-tendon interface were seen and the failure loads observed were far beyond the tension forces that can be expected intraoperatively. Hence, the single-suture graft preparation technique may be a valuable alternative to the conventional technique.

Indexed as

Suture TechniquesAnimalsAnterior Cruciate LigamentAnterior Cruciate Ligament ReconstructionSwineTendonsTibiaACL reconstructionAnterior cruciate ligamentArthroscopyBiomechanicsHamstring graftPatient safety

Identifiers

PMID31980876
PMCPMC7109177

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.