ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2020
Retrograde three-dimensional rotational angiography: A novel method for the detection of plaque protrusion during carotid artery stenting under continuous distal balloon protection.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo prevent ischemic complications during carotid artery stenting, accurate detection of plaque protrusion and appropriate additional treatment are essential. Here, we introduce a novel method for the detection of plaque protrusion under distal balloon protection using three-dimensional rotation angiography-"retrograde 3DRA." We evaluated the safety and efficacy of this method. MATERIALS AND
methodsWe retrospectively analyzed 28 consecutive carotid artery stenting procedures under distal balloon protection at our hospital between July 2017 and August 2019. The first line of protection was dual balloon protection (proximal and distal balloon). After stent deployment, balloon dilatation, and subsequent blood aspiration, 3DRA was performed with the injection of diluted contrast medium from the aspiration catheter positioned just proximal to the distal protection balloon. The stent lumen was analyzed by obtaining the reconstruction maximum intensity projection image.
resultsAmong the 28 cases, all cases could be assessed for in-stent plaque protrusion using "retrograde 3DRA." We were able to evaluate the stent lumen clearly. There were three cases (10.7%) in which plaque protrusion could be confirmed. Since additional balloon dilatation was performed for all protrusion cases under continuing balloon protection, no ischemic complications occurred.
conclusionRetrograde 3DRA could be safe and useful for the detection of plaque protrusions and to avoid ischemic complication for tolerable cases of internal carotid artery transient balloon protection.