Evidence map›Paper›PMID 31979227›Full record

ArticleMaterials (Basel, Switzerland)2020

The Functional Properties of Mg-Zn-X Biodegradable Magnesium Alloys.

Dmitry Merson, Alexander Brilevsky, Pavel Myagkikh, Alexandra Tarkova, Alexei Prokhorikhin, Evgeny Kretov, Tatiana Frolova, Alexei Vinogradov

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 39 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Dmitry MersonInstitute of Advanced Technologies, Togliatti State University, 445667 Togliatti, Russia.
Alexander BrilevskyInstitute of Advanced Technologies, Togliatti State University, 445667 Togliatti, Russia.
Pavel MyagkikhInstitute of Advanced Technologies, Togliatti State University, 445667 Togliatti, Russia.
Alexandra TarkovaCentre for Interventional Cardiology, E.N. Meshalkin National Medical Research Centre, 630055 Novosibirsk, Russia.
Alexei ProkhorikhinCentre for Interventional Cardiology, E.N. Meshalkin National Medical Research Centre, 630055 Novosibirsk, Russia.
Evgeny KretovCentre for Interventional Cardiology, E.N. Meshalkin National Medical Research Centre, 630055 Novosibirsk, Russia.
Tatiana FrolovaDepartment of Plant Genetics, Institute of Cytology and Genetics of the Siberian Branch of the Russian Academy of Science, 630090 Novosibirsk, Russia.
Alexei VinogradovDepartment of Mechanical and Industrial Engineering, Norwegian University of Science and Technology-NTNU, N-7491 Trondheim, Norway.
Meshalkin National Medical Research Center · RUTogliatti State University · RUNorwegian University of Science and Technology · NONovosibirsk State University · RU

Funding

Ministry of Education and Science of the Russian Federation RFMEFI58317X0070
6 · The paper itself

Abstract

The implantation of metallic devices in orthopaedic surgical procedures and coronary angioplasty is associated with the risk of various adverse events: (i) mechanical (premature failure), (ii) chemo-mechanical (corrosion and corrosion-fatigue degradation) and (iii) biomedical (chronic local inflammatory reactions, tissue necrosis, etc.). In this regard, the development of biodegradable implants/stents, which provide the necessary mechanical support for the healing period of the bone or the vessel wall and then are completely resorbed, has bright prospects. Magnesium alloys are the most suitable candidates for that purpose due to their superior mechanical performance, bioresorbability and biocompatibility. This article presents the results of the comparative research on several wrought biodegradable alloys, assessing their potential for biomedical applications. The Mg-Zn-X alloys with different chemical compositions and microstructures were produced using severe plastic deformation techniques. Functional properties pivotal for biomedical applications-mechanical strength, in vitro corrosion resistance and cytotoxic activity-were included in the focus of the study. Excellent mechanical performance and low cytotoxic effects are documented for all alloys with a notable exception for one of two Mg-Zn-Zr alloys. The in vitro corrosion resistance is, however, below expectations due to critical impurities, and this property has yet to be drastically improved through the cleaner materials fabrication processing before they can be considered for biomedical applications.

Indexed as

bioresorbabale implantscorrosioncytotoxicitydeformation processingmagnesium alloymechanical propertiesmicrostructure

Identifiers

PMID31979227
PMCPMC7040658
OpenAlexW3002090543

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked