ArticleClinical spine surgery2020
MagnetOs, Vitoss, and Novabone in a Multi-endpoint Study of Posterolateral Fusion: A True Fusion or Not?
Article in Clinical spine surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 23 citations in OpenAlex.
- A single-arm retrospective feasibility study of biphasic calcium phosphate bone graft with submicron surface topography in anterior cervical discectomy and fusion (ACDF) procedures 6 months postoperative.Journal of spine surgery (Hong Kong) · 2026Article
- In Vivo Study of Bone Growth Around Additively Manufactured Implants With Ti-6Al-4V and Bioactive Glass Powder Composites.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025Article
- Preclinical evaluation of lateral interbody fusions using 3D printed PEEK or 3D printed titanium cages.North American Spine Society journal · 2025Article
- Bone regeneration using moldable calcium phosphate with and without recombinant human BMP-2 in a rabbit critical-sized metaphyseal core defect model.Journal of orthopaedic surgery and research · 2025Article
- Ceramic substitutes, failure to achieve solid fusion in posterolateral instrumented fusion: a surgical and histological evaluation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025Article
- Collagen-hydroxyapatite based scaffolds for bone trauma and regeneration: recent trends and future perspectives.Nanomedicine (London, England) · 2024Review
- Osteoimmunology: Interactions With the Immune System in Spinal Fusion.International journal of spine surgery · 2023Article
- Safety and Efficacy of Stand-Alone Bioactive Glass Injectable Putty or Granules in Posterior Vertebral Fusion for Adolescent Idiopathic and Non-Idiopathic Scoliosis.Children (Basel, Switzerland) · 2023Article
- Design and clinical application of injectable hydrogels for musculoskeletal therapy.Bioengineering & translational medicine · 2022Review
- Physico-Chemical Characteristics and Posterolateral Fusion Performance of Biphasic Calcium Phosphate with Submicron Needle-Shaped Surface Topography Combined with a Novel Polymer Binder.Materials (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
STUDY
designThis study was a multi-endpoint analysis of bone graft substitutes implanted as a standalone graft in a clinically relevant Ovine model of instrumented posterolateral spinal fusion (PLF).
objectiveThe objective of this study was to obtain high-quality evidence on the efficacy of commercial bone graft substitutes compared with autograft in instrumented PLF using a state-of-the-art model with a complete range of assessment techniques. SUMMARY OF BACKGROUND DATA: Preclinical and clinical data on the quality of spinal fusions obtained with bone graft substitutes are often limited. Calcium phosphates with submicron topography have shown promising results in PLF, as these are able to induce bone formation in tissues distant from the host bone, which facilitates bony union.
methodsNine female, skeletally mature sheep (4-5 y) underwent posterior pedicle screw/rods instrumented PLF at L2-L3 and L4-L5 using the following bone graft materials as a standalone graft per spinal segment: (1) biphasic calcium phosphate with submicron topography (BCP<µm), (2) 45S5 Bioglass (BG), and (3) collagen-β-tricalcium phosphate with a 45S5 Bioglass adjunct (TCP/BG). Autograft bone (AB) was used as a positive control treatment. Twelve weeks after implantation, the spinal segments were evaluated by fusion assessment (manual palpation, x-ray, micro-computed tomography, and histology), fusion mass volume quantification (micro-computed tomography), range of motion (ROM) testing, histologic evaluation, and histomorphometry.
resultsFusion assessment revealed equivalence between AB and BCP<µm by all fusion assessment methods, whereas BG and TCP/BG led to significantly inferior results. Fusion mass volume was highest for BCP<µm, followed by AB, BG, and TCP/BG. ROM testing determined equivalence for spinal levels treated with AB and BCP<µm, while BG and TCP/BG exhibited higher ROM. Histologic evaluation revealed substantial bone formation in the intertransverse regions for AB and BCP<µm, whereas BG and TCP/BG grafts contained fibrous tissue and minimal bone formation. Histologic observations were supported by the histomorphometry data.
conclusionsThis study reveals clear differences in efficacy between commercially available bone graft substitutes, emphasizing the importance of clinically relevant animal models with multiendpoint analyses for the evaluation of bone graft materials. The results corroborate the efficacy of calcium phosphate with submicron topography, as this was the only material that showed equivalent performance to autograft in achieving spinal fusion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.