ArticleClinical neuroradiology2021
Low-Profile Laser-Cut Stents for Endovascular Treatment of Intracranial Aneurysms : Incidence, Clinical Presentation and Risk Factors of Thromboembolic Events.
Article in Clinical neuroradiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Machine Learning for Predicting Thromboembolic Events Following Flow Diverter Treatment of Intracranial Aneurysms: A Multicenter Retrospective Study.Neurology and therapy · 2025Article
- WEB embolization of very broad-based intracranial aneurysms with a dome-to-neck ratio ≤ 1.1.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Article
- Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023Article
- Comparative assessment of woven endobridge embolization and standard coil occlusion for the treatment of ruptured basilar tip aneurysms.Neuroradiology · 2023Article
- Results of Temporary Stent-assisted Coil Embolization (CATS) for the Treatment of Wide-neck Aneurysms : A 10-year Single Center Experience.Clinical neuroradiology · 2023Article
- Comparison of angiographic outcomes and complication rates of WEB embolization and coiling for treatment of unruptured basilar tip aneurysms.Scientific reports · 2022Article
- Propensity score-adjusted analysis on stent-assisted coiling versus coiling alone for ruptured intracranial aneurysms.Scientific reports · 2021Article
- Multicenter Postmarket Analysis of the Neuroform Atlas Stent for Stent-Assisted Coil Embolization of Intracranial Aneurysms.AJNR. American journal of neuroradiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeLow-profile intracranial stents are characterized by a miniaturized design that enables deployment via a 0.0165″ or 0.017″ internal diameter microcatheter, which is typically intended for coil delivery. This study analyzed the incidence, clinical relevance and risk factors of thromboembolic events (TEE) occurring during low-profile stent-assisted coiling of intracranial aneurysms.
methodsThis was a retrospective, multicenter analysis of consecutive patients who underwent stent-assisted aneurysm coiling (SAC) with the laser-cut Acandis Acclino and Neuroform Atlas stents. The study evaluated the incidence of symptomatic and asymptomatic TEEs and the impact on functional outcome. Risk factors for TEEs were determined by univariate and bivariate logistic regression analyses.
resultsAmong 131 procedures (mean patient age 56.5 ± 12.8 years, mean aneurysm size: 6.7 ± 3.9 mm) TEEs occurred in 14 cases (10.7%) of which 2 patients (1.5%) developed ischemic stroke, while the remaining TEEs remained asymptomatic. Multivariate analysis revealed Y‑stenting as potential risk factor for TEEs (odds ratio: 3.9, 95% confidence interval: 1.0-16.5; p = 0.08).
conclusionThe use of SAC with low-profile intracranial stents is associated with a favorable safety profile; however, Y‑stenting may carry an increased risk of TEEs, which needs to be considered during treatment planning.
Indexed as
Identifiers
31970465What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.