Evidence map›Paper›PMID 31970354›Full record

ArticleLab on a chip2020

Microphysiological heart-liver body-on-a-chip system with a skin mimic for evaluating topical drug delivery.

Camilly P Pires de Mello, Carlos Carmona-Moran, Christopher W McAleer, Julian Perez, Elizabeth A Coln, Christopher J Long, Carlota Oleaga, Anne Riu, Reine Note, Silvia Teissier and 2 more

Abstract read
In one paragraph

Article in Lab on a chip, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Modeling the Effects of Protracted Cosmic Radiation in a Human Organ-on-Chip Platform.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  15. Microphysiological systems to advance human pathophysiology and translational medicine.Journal of applied physiology (Bethesda, Md. : 1985) · 2024
    Review
  16. Review
  17. Article
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Camilly P Pires de MelloNanoScience Technology Center, University of Central Florida, Orlando, FL 32826, USA. jhickman@ucf.edu.
Carlos Carmona-MoranNanoScience Technology Center, University of Central Florida, Orlando, FL 32826, USA. jhickman@ucf.edu.
Christopher W McAleerHesperos, Inc., Orlando, FL 32826, USA.
Julian PerezNanoScience Technology Center, University of Central Florida, Orlando, FL 32826, USA. jhickman@ucf.edu.
Elizabeth A ColnNanoScience Technology Center, University of Central Florida, Orlando, FL 32826, USA. jhickman@ucf.edu.
Christopher J LongHesperos, Inc., Orlando, FL 32826, USA.
Carlota OleagaNanoScience Technology Center, University of Central Florida, Orlando, FL 32826, USA. jhickman@ucf.edu.
Anne RiuL'Oreal Research, and Innovation Division, Aulnay-sous-Bois, France.
Reine NoteL'Oreal Research, and Innovation Division, Aulnay-sous-Bois, France.
Silvia TeissierL'Oreal Research, and Innovation Division, Aulnay-sous-Bois, France.
Jessica LangerL'Oreal Research, and Innovation Division, Clark, NJ, USA.
James J HickmanNanoScience Technology Center, University of Central Florida, Orlando, FL 32826, USA. jhickman@ucf.edu and Hesperos, Inc., Orlando, FL 32826, USA.ORCID 0000-0002-1621-3006

Funding

Populating MPS database with data from multi-organ, human-on-a-chip microphysiological systemsR44TR001326 · NCATS · HESPEROS, LLC · PI HICKMAN, JAMES J, SHULER, MICHAEL L · 2016 to 2021
$6.5M
NCATS NIH HHS R44 TR001326
6 · The paper itself

Abstract

Body-on-a-chip in vitro systems are a promising technology that aims to increase the predictive power of drug efficacy and toxicity in humans when compared to traditional animal models. Here, we developed a new heart-liver body-on-a-chip system with a skin surrogate to assess the toxicity of drugs that are topically administered. In order to test the utility of the system, diclofenac, ketoconazole, hydrocortisone and acetaminophen were applied topically through a synthetic skin surrogate (Strat-M membrane) and the toxicity results were compared to those of acute drug exposure from systemically applying the compounds. The heart-liver system was successful in predicting the effects for both cardiac and liver functions changes due to the compounds. The difference in the concentrations of drugs applied topically compared to systemically indicates that the barrier properties of the skin surrogate were efficient. One important advantage of this heart-liver system was the capability of showing differential effects of acute and chronic drug exposure which is necessary as part of the International Conference in Harmonisation (ICH) tri-partate guidelines. In conclusion, this work indicates a promising heart-liver body-on-a-chip system that can be used for the assessment of potential drug toxicity from dermal absorption as well as evaluate transport dynamics through the skin in the same system.

Indexed as

Lab-On-A-Chip DevicesPharmaceutical PreparationsAnimalsHumansLiverSkinSkin AbsorptionPharmaceutical Preparations

Identifiers

PMID31970354
PMCPMC7123528

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.