ArticleJournal of orthopaedic surgery and research2020
Prediction of wear performance in femoral and tibial conformity in patient-specific cruciate-retaining total knee arthroplasty.
Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Minimally invasive medial femoral approach to total knee arthroplasty improves short-term outcomes compared to the standard medial parapatellar approach: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2023Pooled it
- Medial unicompartmental knee arthroplasty wear prediction using a total knee joint finite element model.Frontiers in bioengineering and biotechnology · 2025Article
- Investigation of customized total knee implant with articular cartilage under loading conditions using finite element analysis.PloS one · 2025Article
- Robotic-assisted differential total knee arthroplasty with patient-specific implants: surgical techniques and preliminary results.Arthroplasty (London, England) · 2024Article
- Mechanical alignment tolerance of a cruciate-retaining knee prosthesis under gait loading-A finite element analysis.Frontiers in bioengineering and biotechnology · 2023Article
- [Effectiveness comparison of partial versus intact posterior cruciate ligament-retaining in total knee arthroplasty with cruciate-retaining prosthesis].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2021Article
- Biomechanical and Clinical Effect of Patient-Specific or Customized Knee Implants: A Review.Journal of clinical medicine · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundArticular surface curvature design is important in tibiofemoral kinematics and the contact mechanics of total knee arthroplasty (TKA). Thus far, the effects of articular surface curvature have not been adequately discussed with respect to conforming, nonconforming, and medial pivot designs in patient-specific TKA. Therefore, this study evaluates the underlying relationship between the articular surface curvature geometry and the wear performance in patient-specific TKA.
methodsWe compare the wear performances between conventional and patient-specific TKA under gait loading conditions using a computational simulation. Patient-specific TKAs investigated in the study are categorized into patient-specific TKA with conforming articular surfaces, medial pivot patient-specific TKA, and bio-mimetic patient-specific TKA with a patient's own tibial and femoral anatomy. The geometries of the femoral components in patient-specific TKAs are identical.
resultsThe anterior-posterior and internal-external kinematics change with respect to different TKA designs. Moreover, the contact pressure and area did not directly affect the wear performance. In particular, conforming patient-specific TKAs exhibit the highest volumetric wear and wear rate. The volumetric wear in a conforming patient-specific TKA is 29% greater than that in a medial pivot patient-specific TKA.
conclusionThe findings in this study highlight that conformity changes in the femoral and tibial inserts influence the wear performance in patient-specific TKA. Kinematics and contact parameters should be considered to improve wear performance in patient-specific TKA. The conformity modification in the tibiofemoral joint changes the kinematics and contact parameters, and this affects wear performance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.