Evidence map›Paper›PMID 31968532›Full record

ArticleSensors (Basel, Switzerland)2020

Retrieval and Timing Performance of Chewing-Based Eating Event Detection in Wearable Sensors.

Rui Zhang, Oliver Amft

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Rui ZhangChair of Digital Health, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Henkestraße 91, 91052 Erlangen, Germany.ORCID 0000-0001-5815-1598
Oliver AmftChair of Digital Health, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Henkestraße 91, 91052 Erlangen, Germany.ORCID 0000-0001-6811-3659
Friedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We present an eating detection algorithm for wearable sensors based on first detecting chewing cycles and subsequently estimating eating phases. We term the corresponding algorithm class as a bottom-up approach. We evaluated the algorithm using electromyographic (EMG) recordings from diet-monitoring eyeglasses in free-living and compared the bottom-up approach against two top-down algorithms. We show that the F1 score was no longer the primary relevant evaluation metric when retrieval rates exceeded approx. 90%. Instead, detection timing errors provided more important insight into detection performance. In 122 hours of free-living EMG data from 10 participants, a total of 44 eating occasions were detected, with a maximum F1 score of 99.2%. Average detection timing errors of the bottom-up algorithm were 2.4 ± 0.4 s and 4.3 ± 0.4 s for the start and end of eating occasions, respectively. Our bottom-up algorithm has the potential to work with different wearable sensors that provide chewing cycle data. We suggest that the research community report timing errors (e.g., using the metrics described in this work).

Indexed as

Smart GlassesAdultAlgorithmsDietElectromyographyFemaleHumansMaleMasticationMonitoring, PhysiologicSignal Processing, Computer-AssistedTemporal Muscleautomated dietary monitoringbiomedical signal processingeating detectioneating timing error analysissmart eyeglasseswearable health monitoring

Identifiers

PMID31968532
PMCPMC7014527
OpenAlexW3000269942

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.