ArticleJAMA network open2020
Assessment of Mandibular Movement Monitoring With Machine Learning Analysis for the Diagnosis of Obstructive Sleep Apnea.
Article in JAMA network open, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 46 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Analysis of Mandibular Movements to Optimize Ventilatory Management of Children With Obstructive Sleep Apnea Syndrome Treated With Continuous Positive Airway Pressure or Non-Invasive Ventilation.
Sunrise in Obstructive Sleep Apnoea Study (SOSA) A Comparison of the Sunrise Mandibular Movement Monitoring Device With Overnight Oximetry and WatchPAT in the Diagnosis and Management of Obstructive Sleep Apnoea.
Who cites it
46 citing papers in PubMed, 1 synthesis or guideline pooled it, 84 citations in OpenAlex.
- Home-testing devices for diagnosing obstructive sleep apnoea hypopnoea syndrome - a systematic review and economic evaluation.Health technology assessment (Winchester, England) · 2026Pooled it
- Validation of the Sleepiz One + as a radar-based sensor for contactless diagnosis of sleep apnea.Sleep & breathing = Schlaf & Atmung · 2024Trial
- Mandibular movement monitor provides faster, yet accurate diagnosis for obstructive sleep apnoea: A randomised controlled study.Clinical medicine (London, England) · 2024Trial
- Multimodal Hydrogel-Based Sensors for Sleep Respiratory Monitoring: Signal Sensing Mechanisms and Structural Design Strategies.Sensors (Basel, Switzerland) · 2026Review
- Mandibular Movement Monitoring in Children With Neurodisability.Pediatric pulmonology · 2026Article
- Zero burden multi night monitoring with AI enabled technology reduces obstructive sleep apnea misdiagnosis.NPJ digital medicine · 2026Article
- From classic to cutting-edge: technological approaches to respiratory physiological signals in assessing sleep-disordered breathing.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2026Review
- Time to diagnosis and treatment of obstructive sleep apnoea using mandibular jaw movement monitoring versus polysomnography: an open-label, multicentre, randomised, controlled trial.The Lancet regional health. Europe · 2026Article
- Respiratory effort burden measured by mandibular jaw movements as a digital marker with clinical insights in obstructive sleep apnea.Communications medicine · 2026Article
- Nocturnal blood pressure burden: towards a better understanding of the OSA-hypertension relationship.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025Article
- Obstructive sleep apnea severity varies by season and environmental influences such as ambient temperature.Communications medicine · 2025Article
- Exploring the Dose-Response Relationship between Mandibular Protrusion and Respiratory Effort Burden in Oral Appliance Therapy for Obstructive Sleep Apnea.Annals of the American Thoracic Society · 2025Article
- Multistate Modeling for Determining Transition Probabilities in Sleep Apnea Severity Across Multiple Nights of Recording.CHEST pulmonary · 2025Article
- OSA diagnosis in context: a comprehensive approach to evaluating novel diagnostic devices.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025Article
- Diagnostic Modalities in Sleep Disordered Breathing: Current and Emerging Technology and Its Potential to Transform Diagnostics.Respirology (Carlton, Vic.) · 2025Review
- The complexity of employing "optimal AHI/RDI cutoffs" in assessing the performance of OSA-detecting wearables.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025Article
- Enhancing artificial intelligence-driven sleep apnea diagnosis: The critical importance of input signal proficiency with a focus on mandibular jaw movements.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2025Article
- Harnessing Artificial Intelligence in Obesity Research and Management: A Comprehensive Review.Diagnostics (Basel, Switzerland) · 2025Review
- Responses to questions about Sunrise in the review on OSA wearables by Chiang et al.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025Article
- Redefining telemedicine in obstructive sleep apnea management through artificial intelligence.Frontiers in sleep · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Given the high prevalence of obstructive sleep apnea (OSA), there is a need for simpler and automated diagnostic approaches. Objective: To evaluate whether mandibular movement (MM) monitoring during sleep coupled with an automated analysis by machine learning is appropriate for OSA diagnosis. Design, Setting, and Participants: Diagnostic study of adults undergoing overnight in-laboratory polysomnography (PSG) as the reference method compared with simultaneous MM monitoring at a sleep clinic in an academic institution (Sleep Laboratory, Centre Hospitalier Universitaire Université Catholique de Louvain Namur Site Sainte-Elisabeth, Namur, Belgium). Patients with suspected OSA were enrolled from July 5, 2017, to October 31, 2018. Main Outcomes and Measures: Obstructive sleep apnea diagnosis required either evoking signs or symptoms or related medical or psychiatric comorbidities coupled with a PSG-derived respiratory disturbance index (PSG-RDI) of at least 5 events/h. A PSG-RDI of at least 15 events/h satisfied the diagnosis criteria even in the absence of associated symptoms or comorbidities. Patients who did not meet these criteria were classified as not having OSA. Agreement analysis and diagnostic performance were assessed by Bland-Altman plot comparing PSG-RDI and the Sunrise system RDI (Sr-RDI) with diagnosis threshold optimization via receiver operating characteristic curves, allowing for evaluation of the device sensitivity and specificity in detecting OSA at 5 events/h and 15 events/h. Results: Among 376 consecutive adults with suspected OSA, the mean (SD) age was 49.7 (13.2) years, the mean (SD) body mass index was 31.0 (7.1), and 207 (55.1%) were men. Reliable agreement was found between PSG-RDI and Sr-RDI in patients without OSA (n = 46; mean difference, 1.31; 95% CI, -1.05 to 3.66 events/h) and in patients with OSA with a PSG-RDI of at least 5 events/h with symptoms (n = 107; mean difference, -0.69; 95% CI, -3.77 to 2.38 events/h). An Sr-RDI underestimation of -11.74 (95% CI, -20.83 to -2.67) events/h in patients with OSA with a PSG-RDI of at least 15 events/h was detected and corrected by optimization of the Sunrise system diagnostic threshold. The Sr-RDI showed diagnostic capability, with areas under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.96) and 0.93 (95% CI, 0.90-0.93) for corresponding PSG-RDIs of 5 events/h and 15 events/h, respectively. At the 2 optimal cutoffs of 7.63 events/h and 12.65 events/h, Sr-RDI had accuracy of 0.92 (95% CI, 0.90-0.94) and 0.88 (95% CI, 0.86-0.90) as well as posttest probabilities of 0.99 (95% CI, 0.99-0.99) and 0.89 (95% CI, 0.88-0.91) at PSG-RDIs of at least 5 events/h and at least 15 events/h, respectively, corresponding to positive likelihood ratios of 14.86 (95% CI, 9.86-30.12) and 5.63 (95% CI, 4.92-7.27), respectively. Conclusions and Relevance: Automatic analysis of MM patterns provided reliable performance in RDI calculation. The use of this index in OSA diagnosis appears to be promising.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.