Evidence map›Paper›PMID 31967356›Full record

ArticleJournal of clinical laboratory analysis2020

Identification of and solution for false D-dimer results.

Xian-Yan Zhang, Xue-Xuan Zhang, Jia-Long Xu, Teng-Yi Huang, Ying Wu, Ye-Ru Yang, Huan-Bin Zhou, Ying-E Wu

Abstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Identification of and solution for false D-dimer results.Journal of clinical laboratory analysis · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xian-Yan ZhangDepartment of Laboratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Xue-Xuan ZhangDepartment of Laboratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Jia-Long XuDepartment of Laboratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Teng-Yi HuangDepartment of Laboratory Medicine, The Second Affiliated Hospital of Shantou University Medical College, Shantou, China.
Ying WuDepartment of Laboratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Ye-Ru YangDepartment of Laboratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Huan-Bin ZhouDepartment of Laboratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Ying-E WuDepartment of Laboratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China.ORCID https://orcid.org/0000-0001-7135-1391

Funding

National Natural Science Foundation of China 81302540
6 · The paper itself

Abstract

backgroundClinically, D-dimer (DD) levels are mainly used to exclude diseases such as deep venous thrombosis (DVT). In clinical testing, DD assays can be subjected to interference that may cause false results, which directly affect the clinical diagnosis. Our hypothesis was that the 95% confidence intervals (CIs) of the fibrin degradation product (FDP)/DD and fibrinogen (Fib)/DD ratios were used to identify these false results and corrected via multiple dilutions.

methodsIn total, 16 776 samples were divided into three groups according to the DD levels detected by Sysmex CS5100 and CA7000: Group A, DD ≥ 2.0 μg/mL fibrinogen equivalent unit (FEU); group B, 0.5 < DD < 2.0 μg/mL FEU; and group C, DD ≤ 0.5 μg/mL FEU. The 95% CIs of the FDP/DD and Fib/DD ratios were calculated. Six abnormal DD results were found according to the 95% CIs. For verification, we performed multiple dilutions, compared the results with those of other instruments, and tested the addition of heterophilic blocking reagent (HBR).

resultsThe median and 95% CI of the FDP/DD ratio were 3.76 and 2.25-8.15 in group A, 5.63 and 2.86-10.58 in group B, 10.23 and 0.91-47.71 in groups C, respectively. For the Fib/DD ratio, the 95% CIs was 0.02-2.21 in group A, 0.68-8.15 in group B, and 3.82-55.27 in groups C. Six abnormal results were identified after multiple dilutions, by comparison with other detection systems, and after HBR addition.

conclusionsThe FDP/DD ratio is more reliable for identifying false results. If the FDP/DD ratio falls outside the 95% CI, it should be verified by different methods.

Indexed as

AdultArtifactsConfidence IntervalsFalse Positive ReactionsFemaleFibrin Fibrinogen Degradation ProductsHumansImmunoturbidimetryMaleMiddle AgedPregnancyVenous ThrombosisFibrin Fibrinogen Degradation Productsfibrin fragment D95% CID-dimerfalse resultfibrin degradation productheterophilic antibody

Identifiers

PMID31967356
PMCPMC7307351

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.