Evidence map›Paper›PMID 31967221›Full record

ArticleRevista Brasileira de terapia intensiva

Cardiac output measured by transthoracic echocardiography and Swan-Ganz catheter. A comparative study in mechanically ventilated patients with high positive end-expiratory pressure.

José Gorrasi, Arturo Pazos, Lucia Florio, Carlos Américo, Natalia Lluberas, Gabriel Parma, Ricardo Lluberas

Open access · diamondAbstract readComparative Study
In one paragraph

Article in Revista Brasileira de terapia intensiva. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

José GorrasiCátedra de Medicina Intensiva y Centro de Tratamiento Intensivo, Facultad de Medicina, Universidad de la República - Montevideo, Uruguay.ORCID http://orcid.org/0000-0001-6308-5732
Arturo PazosCátedra de Cardiología, Hospital de Clínicas, Facultad de Medicina, Universidad de la República - Montevideo, Uruguay.
Lucia FlorioCátedra de Cardiología, Hospital de Clínicas, Facultad de Medicina, Universidad de la República - Montevideo, Uruguay.
Carlos AméricoCátedra de Cardiología, Hospital de Clínicas, Facultad de Medicina, Universidad de la República - Montevideo, Uruguay.
Natalia LluberasCátedra de Cardiología, Hospital de Clínicas, Facultad de Medicina, Universidad de la República - Montevideo, Uruguay.
Gabriel ParmaCátedra de Cardiología, Hospital de Clínicas, Facultad de Medicina, Universidad de la República - Montevideo, Uruguay.
Ricardo LluberasCátedra de Cardiología, Hospital de Clínicas, Facultad de Medicina, Universidad de la República - Montevideo, Uruguay.
Universidad de la República · UY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare cardiac output measurements by transthoracic echocardiography and a pulmonary artery catheter in mechanically ventilated patients with high positive end-expiratory pressure. To evaluate the effect of tricuspid regurgitation.

methodsSixteen mechanically ventilated patients were studied. Cardiac output was measured by pulmonary artery catheterization and transthoracic echocardiography. Measurements were performed at different levels of positive end-expiratory pressure (10cmH2O, 15cmH2O, and 20cmH2O). The effect of tricuspid regurgitation on cardiac output measurement was evaluated. The intraclass correlation coefficient was studied; the mean error and limits of agreement were studied with the Bland-Altman plot. The error rate was calculated.

resultsForty-four pairs of cardiac output measurements were obtained. An intraclass correlation coefficient of 0.908 was found (p < 0.001). The mean error was 0.44L/min for cardiac output values between 5 and 13L/min. The limits of agreement were 3.25L/min and -2.37L/min. With tricuspid insufficiency, the intraclass correlation coefficient was 0.791, and without tricuspid insufficiency, 0.935. Tricuspid insufficiency increased the error rate from 32% to 52%.

conclusionsIn patients with high positive end-expiratory pressure, cardiac output measurement by transthoracic echocardiography is comparable to that with a pulmonary artery catheter. Tricuspid regurgitation influences the intraclass correlation coefficient. In patients with high positive end-expiratory pressure, the use of transthoracic echocardiography to measure cardiac output is comparable to invasive measures.

Indexed as

Positive-Pressure RespirationAgedCardiac OutputCatheterization, Swan-GanzEchocardiographyHumansMiddle AgedRespiration, Artificial

Identifiers

PMID31967221
PMCPMC7008993
OpenAlexW2997488676

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked