Evidence map›Paper›PMID 31963402›Full record

ArticleMicromachines2020

A Robotic Biopsy Endoscope with Magnetic 5-DOF Locomotion and a Retractable Biopsy Punch.

Manh Cuong Hoang, Viet Ha Le, Kim Tien Nguyen, Van Du Nguyen, Jayoung Kim, Eunpyo Choi, Seungmin Bang, Byungjeon Kang, Jong-Oh Park, Chang-Sei Kim

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 53 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Micromachines · 2022
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Manh Cuong HoangDepartment of Mechanical Engineering, Chonnam National University, Gwangju 61186, Korea.ORCID 0000-0001-6816-339X
Viet Ha LeDepartment of Mechanical Engineering, Chonnam National University, Gwangju 61186, Korea.
Kim Tien NguyenDepartment of Mechanical Engineering, Chonnam National University, Gwangju 61186, Korea.ORCID 0000-0003-1260-3610
Van Du NguyenKorea Institute of Medical Microrobotics, Gwangju 61186, Korea.
Jayoung KimKorea Institute of Medical Microrobotics, Gwangju 61186, Korea.
Eunpyo ChoiDepartment of Mechanical Engineering, Chonnam National University, Gwangju 61186, Korea.
Seungmin BangDivision of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul 120-752, Korea.
Byungjeon KangKorea Institute of Medical Microrobotics, Gwangju 61186, Korea.ORCID 0000-0003-1185-1911
Jong-Oh ParkDepartment of Mechanical Engineering, Chonnam National University, Gwangju 61186, Korea.
Chang-Sei KimDepartment of Mechanical Engineering, Chonnam National University, Gwangju 61186, Korea.
Chonnam National University · KRYonsei University · KR

Funding

Korea Health Industry Development Institute HI19C0642
6 · The paper itself

Abstract

Capsule endoscopes (CEs) have emerged as an advanced diagnostic technology for gastrointestinal diseases in recent decades. However, with regard to robotic motions, they require active movability and multi-functionalities for extensive, untethered, and precise clinical utilization. Herein, we present a novel wireless biopsy CE employing active five degree-of-freedom locomotion and a biopsy needle punching mechanism for the histological analysis of the intestinal tract. A medical biopsy punch is attached to a screw mechanism, which can be magnetically actuated to extrude and retract the biopsy tool, for tissue extraction. The external magnetic field from an electromagnetic actuation (EMA) system is utilized to actuate the screw mechanism and harvest biopsy tissue; therefore, the proposed system consumes no onboard energy of the CE. This design enables observation of the biopsy process through the capsule's camera. A prototype with a diameter of 12 mm and length of 30 mm was fabricated with a medical biopsy punch having a diameter of 1.5 mm. Its performance was verified through numerical analysis, as well as in-vitro and ex-vivo experiments on porcine intestine. The CE could be moved to target lesions and obtain sufficient tissue samples for histological examination. The proposed biopsy CE mechanism utilizing punch biopsy and its wireless extraction-retraction technique can advance untethered intestinal endoscopic capsule technology at clinical sites.

Indexed as

active locomotive capsule endoscopebiopsy capsule endoscopebiopsy punching needleelectromagnetic actuationintestinal diagnosis

Identifiers

PMID31963402
PMCPMC7020148
OpenAlexW2998813567

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.