System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015.

Stefan Pleus, Annette Baumstark, Nina Jendrike, Jochen Mende, Manuela Link, Eva Zschornack, Cornelia Haug, Guido Freckmann

Registry-linked trialAbstract readEvaluation Study
In one paragraph

Article in BMJ open diabetes research & care, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03737188 (Institut Fuer Diabetes-Technologie Surveillance Program for Blood Glucose Monitoring Systems in Europe), which is not on this map. Cited by 23 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03737188 nacompletednot on this map

Institut Fuer Diabetes-Technologie Surveillance Program for Blood Glucose Monitoring Systems in Europe

TypeinterventionalSponsorInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität UlmRan2018 to 2018Enrolled126ConditionsDiabetesArmsBlood glucose monitoring systems for self-testing
3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Monitoring of the Analytical Performance of Four Different Blood Glucose Monitoring Systems: A Post-market Performance Follow-Up Study.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2024
    Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Self-Monitoring of Blood Glucose as an Integral Part in the Management of People with Type 2 Diabetes Mellitus.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2022
    Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Stefan PleusInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany stefan.pleus@idt-ulm.de.ORCID http://orcid.org/0000-0003-4629-7754
Annette BaumstarkInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany.
Nina JendrikeInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany.
Jochen MendeInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany.
Manuela LinkInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany.
Eva ZschornackInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany.
Cornelia HaugInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany.
Guido FreckmannInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Universität Ulm, Ulm, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAccuracy of 18 current-generation blood glucose monitoring systems (BGMS) available in Europe was evaluated applying criteria adapted from EN ISO 15197:2015 with one reagent system lot. BGMS were selected based on market research data. RESEARCH DESIGN AND

methodsThe BGMS ABRA, Accu-Chek Guide, AURUM, CareSens Dual, CERA-CHEK 1CODE, ContourNext One, eBsensor, FreeStyle Freedom Lite, GL50 evo, GlucoCheck GOLD, GlucoMen areo 2K, GluNEO, MyStar DoseCoach, OneTouch Verio Flex, Pic GlucoTest, Rightest GM700S, TRUEyou, and WaveSense JAZZ Wireless were tested using capillary blood from 100 different subjects and assessing the percentage of results within ±15 mg/dL (0.83 mmol/L) or 15% of comparison method results for BG concentrations below or above 100 mg/dL (5.55 mmol/L), respectively. In addition, the minimal deviation from comparison method results within which ≥95% of results of the respective BGMS were found was calculated.

resultsIn total, 14 BGMS had ≥95% of results within ±15 mg/dL (0.83 mmol/L) or ±15% and 3 BGMS had ≥95% of results within ±10 mg/dL (0.55 mmol/L) or ±10% of the results obtained with the comparison method. The smallest deviation from comparison method results within which ≥95% of results were found was ±7.7 mg/dL (0.43 mmol/L) or ±7.7%; the highest deviation was ±19.7 mg/dL (1.09 mmol/L) or ±19.7%.

conclusionsThis accuracy evaluation shows that not all CE-labeled BGMS fulfill accuracy requirements of ISO 15197 reliably and that there is considerable variation even among BGMS fulfilling these criteria. This safety-related information should be taken into account by patients and healthcare professionals when making therapy decisions. TRIAL REGISTRATION NUMBER: NCT03737188.

Indexed as

AdultAgedAged, 80 and overBiomarkersBlood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1Diabetes Mellitus, Type 2EuropeFemaleFollow-Up StudiesHumansMaleMiddle AgedPatient Acceptance of Health CarePoint-of-Care SystemsBiomarkersBlood Glucoseaccuracyblood glucose monitorsblood glucose self-monitoringhealth care research

Identifiers

PMID31958308
PMCPMC7039612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.