Evidence map›Paper›PMID 31957964›Full record

ArticleJournal of applied clinical medical physics2020

Observer uncertainties of soft tissue-based patient positioning in IGRT.

Taka-Aki Hirose, Hidetaka Arimura, Jun-Ichi Fukunaga, Saiji Ohga, Tadamasa Yoshitake, Yoshiyuki Shioyama

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Organ-contour-driven auto-matching algorithm in image-guided radiotherapy.Journal of applied clinical medical physics · 2024
    Article
  4. Article
  5. Evaluation of the XVI dual registration tool for image-guided radiotherapy in prostate cancer.Technical innovations & patient support in radiation oncology · 2021
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Taka-Aki HiroseDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Hidetaka ArimuraFaculty of Medical Sciences, Kyushu University, Fukuoka, Japan.
Jun-Ichi FukunagaDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Saiji OhgaDepartment of Clinical Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Tadamasa YoshitakeDepartment of Clinical Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Yoshiyuki ShioyamaDepartment of Clinical Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Kyushu University · JPKyushu University Hospital · JP

Funding

JSPS KAKENHI JP19K16803
6 · The paper itself

Abstract

purposeThere remain uncertainties due to inter- and intraobserver variability in soft-tissue-based patient positioning even with the use of image-guided radiation therapy (IGRT). This study aimed to reveal observer uncertainties of soft-tissue-based patient positioning on cone-beam computed tomography (CBCT) images for prostate cancer IGRT.

methodsTwenty-six patients (7-8 fractions/patient, total number of 204 fractions) who underwent IGRT for prostate cancer were selected. Six radiation therapists retrospectively measured prostate cancer location errors (PCLEs) of soft-tissue-based patient positioning between planning CT (pCT) and pretreatment CBCT (pre-CBCT) images after automatic bone-based registration. Observer uncertainties were evaluated based on residual errors, which denoted the differences between soft-tissue and reference positioning errors. Reference positioning errors were obtained as PCLEs of contour-based patient positioning between pCT and pre-CBCT images. Intraobserver variations were obtained from the difference between the first and second soft-tissue-based patient positioning repeated by the same observer for each fraction. Systematic and random errors of inter- and intraobserver variations were calculated in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions. Finally, clinical target volume (CTV)-to-planning target volume (PTV) margins were obtained from systematic and random errors of inter- and intraobserver variations in AP, SI, and LR directions.

resultsInterobserver variations in AP, SI, and LR directions were 0.9, 0.9, and 0.5 mm, respectively, for the systematic error, and 1.8, 2.2, and 1.1 mm, respectively, for random error. Intraobserver variations were <0.2 mm in all directions. CTV-to-PTV margins in AP, SI, and LR directions were 3.5, 3.8, and 2.1 mm, respectively.

conclusionIntraobserver variability was sufficiently small and would be negligible. However, uncertainties due to interobserver variability for soft-tissue-based patient positioning using CBCT images should be considered in CTV-to-PTV margins.

Indexed as

Observer VariationPatient PositioningAgedAged, 80 and overCone-Beam Computed TomographyHumansMaleMiddle AgedModels, StatisticalProstatic NeoplasmsRadiotherapy DosageRadiotherapy, Image-GuidedRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedReproducibility of ResultsRetrospective Studiesinterobserver variationintraobserver variationprostate cancer image-guided radiation therapyPTV marginsoft-tissue-based patient positioning

Identifiers

PMID31957964
PMCPMC7021001
OpenAlexW3000420357

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.