ArticleJournal of applied clinical medical physics2020
Observer uncertainties of soft tissue-based patient positioning in IGRT.
Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 17 citations in OpenAlex.
- Development of a patient-specific cone-beam computed tomography dose optimization model using machine learning in image-guided radiation therapy.Radiological physics and technology · 2025Article
- Dual-encoder architecture for metal artifact reduction for kV-cone-beam CT images in head and neck cancer radiotherapy.Scientific reports · 2024Article
- Organ-contour-driven auto-matching algorithm in image-guided radiotherapy.Journal of applied clinical medical physics · 2024Article
- Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy.Radiation oncology (London, England) · 2022Article
- Evaluation of the XVI dual registration tool for image-guided radiotherapy in prostate cancer.Technical innovations & patient support in radiation oncology · 2021Article
- Factors affecting accuracy and precision in ultrasound guided radiotherapy.Physics and imaging in radiation oncology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
purposeThere remain uncertainties due to inter- and intraobserver variability in soft-tissue-based patient positioning even with the use of image-guided radiation therapy (IGRT). This study aimed to reveal observer uncertainties of soft-tissue-based patient positioning on cone-beam computed tomography (CBCT) images for prostate cancer IGRT.
methodsTwenty-six patients (7-8 fractions/patient, total number of 204 fractions) who underwent IGRT for prostate cancer were selected. Six radiation therapists retrospectively measured prostate cancer location errors (PCLEs) of soft-tissue-based patient positioning between planning CT (pCT) and pretreatment CBCT (pre-CBCT) images after automatic bone-based registration. Observer uncertainties were evaluated based on residual errors, which denoted the differences between soft-tissue and reference positioning errors. Reference positioning errors were obtained as PCLEs of contour-based patient positioning between pCT and pre-CBCT images. Intraobserver variations were obtained from the difference between the first and second soft-tissue-based patient positioning repeated by the same observer for each fraction. Systematic and random errors of inter- and intraobserver variations were calculated in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions. Finally, clinical target volume (CTV)-to-planning target volume (PTV) margins were obtained from systematic and random errors of inter- and intraobserver variations in AP, SI, and LR directions.
resultsInterobserver variations in AP, SI, and LR directions were 0.9, 0.9, and 0.5 mm, respectively, for the systematic error, and 1.8, 2.2, and 1.1 mm, respectively, for random error. Intraobserver variations were <0.2 mm in all directions. CTV-to-PTV margins in AP, SI, and LR directions were 3.5, 3.8, and 2.1 mm, respectively.
conclusionIntraobserver variability was sufficiently small and would be negligible. However, uncertainties due to interobserver variability for soft-tissue-based patient positioning using CBCT images should be considered in CTV-to-PTV margins.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials